in vitro comparison of working length determination using three different electronic apex locators
Authors
abstract
background: the aim of this study was to compare the accuracy of the apex-locating functions of dentaport zx, raypex 5 and endo master electronic apex locators (eals) in vitro. materials and methods: thirty extracted human single-rooted teeth with mature apices were used for the study. the real working length (rwl) was established by subtracting 0.5 mm from the actual root canal length. all teeth were mounted in an alginate model that was especially developed to test the eals and the teeth were then measured with each eal. the results were compared with the corresponding rwl, which was subtracted from the electronically determined distance. data were analyzed using a paired-samples t-test, a chi-square test and a repeated measure analysis of variance evaluation at the 0.05 level of signifi cance. results: statistical analysis showed that no signifi cant difference was found among all eals (p > 0.05). conclusion: the accuracy of the eals was evaluated and all of the devices showed an acceptable determination of electronic working length between the ranges of ±0.5 mm. key words: dentaport zx, electronic apex locator, endo master, raypex 5, working length
similar resources
In vitro comparison of working length determination using three different electronic apex locators
BACKGROUND The aim of this study was to compare the accuracy of the apex-locating functions of DentaPort ZX, Raypex 5 and Endo Master electronic apex locators (EALs) in vitro. MATERIALS AND METHODS Thirty extracted human single-rooted teeth with mature apices were used for the study. The real working length (RWL) was established by subtracting 0.5 mm from the actual root canal length. All tee...
full textClinical Efficacy of Three Different Electronic Apex Locators in Comparison with Radiographic Working Length Determination
The aim of this study was to test the efficacy of three different electronic apex locators (EALs) in comparison with the radiographic working length determination. This study was conducted on the 211 root canals of 113 teeth in the undergraduate endodontic clinic. Under the referee of the research assistants, the students determined the working length by taking a periapical radiograph with the ...
full textIn vitro comparison of three electronic apex locators.
INTRODUCTION The purpose of this study was to compare the accuracy of the Root ZX II Apex Locator (RZX), the Elements Apex Locator (ELE), and the Precision Apex Locator (PAL). METHODS Forty single-rooted extracted teeth were decoronated and the root canals coronally flared. Actual canal lengths were determined by inserting a #10 file until the tip was visualized (12.8x magnification) just wit...
full textComparison of working length determination with radiographs and four electronic apex locators.
AIM To evaluate the accuracy of the Root ZX, Elements-Diagnostic, Precision AL and Raypex 5 electronic apex locators when compared to radiographs for locating the apical constriction. METHODOLOGY The apical constriction of 693 canals in 245 maxillary and mandibular teeth was located in vivo with four electronic apex locators (EALs) and radiographically. After extraction the actual location of...
full textElectronic Apex Locators and Conventional Radiograph in Working Length Measurement
The success of endodontic treatment is highly dependent on the adequate three-dimensional cleaning, shaping, disinfection, and obturation of the root canal system. It is universally accepted that the correct determination of the working length (WL) is one of the crucial steps in the process of a successful treatment. It is believed that root canal preparation and filling should be kept inside t...
full textIn vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination
In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...
full textMy Resources
Save resource for easier access later
Journal title:
dental research journalجلد ۱۱، شماره ۵، صفحات ۰-۰
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023