effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentin
Authors
abstract
background: the aim of this study was to determine the microtensile bond strength (μtbs) of ceramic and composite computer aided design‑computer aided manufacturing (cad‑cam) blocks bonded to dentin using different adhesive strategies. materials and methods: in this in vitro study, 30 crowns of sound freshly extracted human molars were sectioned horizontally 3 mm above the cementoenamel junction to produce flat dentin surfaces. ceramic and composite cad/cam blocks, size 14, were sectioned into slices of 3 mm thick. before bonding, cad/cam block surfaces were treated according to the manufacturer’s instructions. groups were created based on the adhesive strategy used: group 1 (gi) – conventional resin cement + total‑etch adhesive system, group 2 (gii) – conventional resin cement + self‑etch adhesive system, and group 3 (giii) – self‑adhesive resin cement with no adhesive. bonded specimens were stored in 100% humidity for 24h at 37°c, and then sectioned with a slow‑speed diamond saw to obtain 1 mm × 1 mm × 6 mm microsticks. microtensile testing was then conducted using a microtensile tester. μtbs values were expressed in mpa and analyzed by one‑way anova with post hoc (tukey) test at the 5% significance le vel. results: mean values and standard deviations of μtbs (mpa) were 17.68 (±2.71) for gi/ceramic; 17.62 (±3.99) for gi/composite; 13.61 (±6.92) for gii/composite; 12.22 (±4.24) for gii/ceramic; 7.47 (±2.29) for giii/composite; and 6.48 (±3.10) for giii/ceramic; anova indicated significant differences among the adhesive modality and block interaction ( p < 0.05), and no significant differences among blocks only, except between gi and gii/ceramic. bond strength of giii was consistently lower ( p < 0.05) than gi and gii groups, regardless the block used. conclusion: cementation of cad/cam restorations, either composite or ceramic, can be significantly affected by different adhesive strategies used. key words: adhesion, ceramic, composite resin, computer aided design/computer aided manufacturing
similar resources
influence of different luting protocols on shear bond strength of computer aided design/computer aided manufacturing resin nanoceramic material to dentin
background: the purpose of this study was to evaluate the influence of three different luting protocols on shear bond strength of computer aided design/computer aided manufacturing (cad/cam) resin nanoceramic (rnc) material to dentin. materials and methods: in this in vitro study, 30 disks were milled from rnc blocks (lava ultimate/3m espe) with cad/cam technology. the disks were subsequently c...
full textEffect of different synthetic matrix metalloproteinase inhibitors on composite-dentin microtensile bond strength durability
Background and Aims: Despite patient’s demand increased for tooth color restorations, the stable bond between dentin and composite is a challenge in dentistry. Dentin protease activation is responsible for dentin-resin bond failure. The aim of this study was to determine the best pretreatment agent to inhibit matrix metalloproteinase and increase resin-dentin bond durability. Materials and Met...
full textEffect of salivary contamination on shear bond strength of three different dentin adhesive systems
Effect of salivary contamination on shear bond strength of three different dentin adhesive systems Dr. H. Kermanshah* - Dr. H. Haj miragha** - Dr. SH. Gatoeizadeh*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Tehran University / Medical Sciences. **- Assistant Professor of Fixed Prosthodontics Dept. & Dental Research Center - Faculty of Dentistry – Tehran Unive...
full textAn Overview of Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) in Restorative Dentistry
Objective: To review the current knowledge of CAD/CAM in dentistry and its development in the mentioned field. Sources: An electronic search was conducted across Ovid Medline, complemented by manual search across individual databases, such as Cochrane, Medline and ISI Web of Science databases and Google Scholar for literature analysis on the mentioned topic. The studies were reviewed thoroughly...
full textMicrotensile bond strength of clearfil SE bond to caries-affected dentin and normal dentin
Microtensile bond strength of clearfil SE bond to caries-affected dentin and normal dentin Dr. A. Ghasemi* - Dr. M. Bargrizan** - Dr. M. Mahmoodi*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Pedodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. ***...
full textEffect of conditioner on microtensile bond strength of self-adhesive resin cements to dentin.
OBJECTIVE Evaluate, in vitro, the microtensile bond strength (µTBS) of RelyX ARC conventional resin cement and RelyX Unicem and Maxcem self-adhesive resin cements to dentin, and the influence of polyacrylic acid pretreatment on the µTBS. MATERIAL AND METHODS Flat dentin surfaces were obtained in 15 third molars which were randomly divided into 5 groups: Group 1 - RelyX ARC (control); Group 2 ...