effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentin

Authors

renato roperto

anna akkus

ozan akkus

lisa lang

abstract

background: the aim of this study was to determine the microtensile bond strength (μtbs) of ceramic and composite computer aided design‑computer aided manufacturing (cad‑cam) blocks bonded to dentin using different adhesive strategies. materials and methods: in this in vitro study, 30 crowns of sound freshly extracted human molars were sectioned horizontally 3 mm above the cementoenamel junction to produce flat dentin surfaces. ceramic and composite cad/cam blocks, size 14, were sectioned into slices of 3 mm thick. before bonding, cad/cam block surfaces were treated according to the manufacturer’s instructions. groups were created based on the adhesive strategy used: group 1 (gi) – conventional resin cement + total‑etch adhesive system, group 2 (gii) – conventional resin cement + self‑etch adhesive system, and group 3 (giii) – self‑adhesive resin cement with no adhesive. bonded specimens were stored in 100% humidity for 24h at 37°c, and then sectioned with a slow‑speed diamond saw to obtain 1 mm × 1 mm × 6 mm microsticks. microtensile testing was then conducted using a microtensile tester. μtbs values were expressed in mpa and analyzed by one‑way anova with post hoc (tukey) test at the 5% significance le vel. results: mean values and standard deviations of μtbs (mpa) were 17.68 (±2.71) for gi/ceramic; 17.62 (±3.99) for gi/composite; 13.61 (±6.92) for gii/composite; 12.22 (±4.24) for gii/ceramic; 7.47 (±2.29) for giii/composite; and 6.48 (±3.10) for giii/ceramic; anova indicated significant differences among the adhesive modality and block interaction ( p < 0.05), and no significant differences among blocks only, except between gi and gii/ceramic. bond strength of giii was consistently lower ( p < 0.05) than gi and gii groups, regardless the block used. conclusion: cementation of cad/cam restorations, either composite or ceramic, can be significantly affected by different adhesive strategies used. key words: adhesion, ceramic, composite resin, computer aided design/computer aided manufacturing

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

influence of different luting protocols on shear bond strength of computer aided design/computer aided manufacturing resin nanoceramic material to dentin

background: the purpose of this study was to evaluate the influence of three different luting protocols on shear bond strength of computer aided design/computer aided manufacturing (cad/cam) resin nanoceramic (rnc) material to dentin. materials and methods: in this in vitro study, 30 disks were milled from rnc blocks (lava ultimate/3m espe) with cad/cam technology. the disks were subsequently c...

full text

Effect of different synthetic matrix metalloproteinase inhibitors on composite-dentin microtensile bond strength durability

Background and Aims: Despite patient’s demand increased for tooth color restorations, the stable bond between dentin and composite is a challenge in dentistry. Dentin protease activation is responsible for dentin-resin bond failure. The aim of this study was to determine the best pretreatment agent to inhibit matrix metalloproteinase and increase resin-dentin bond durability. Materials and Met...

full text

Effect of salivary contamination on shear bond strength of three different dentin adhesive systems

Effect of salivary contamination on shear bond strength of three different dentin adhesive systems Dr. H. Kermanshah* - Dr. H. Haj miragha** - Dr. SH. Gatoeizadeh*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Tehran University / Medical Sciences. **- Assistant Professor of Fixed Prosthodontics Dept. & Dental Research Center - Faculty of Dentistry – Tehran Unive...

full text

An Overview of Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) in Restorative Dentistry

Objective: To review the current knowledge of CAD/CAM in dentistry and its development in the mentioned field. Sources: An electronic search was conducted across Ovid Medline, complemented by manual search across individual databases, such as Cochrane, Medline and ISI Web of Science databases and Google Scholar for literature analysis on the mentioned topic. The studies were reviewed thoroughly...

full text

Microtensile bond strength of clearfil SE bond to caries-affected dentin and normal dentin

Microtensile bond strength of clearfil SE bond to caries-affected dentin and normal dentin Dr. A. Ghasemi* - Dr. M. Bargrizan** - Dr. M. Mahmoodi*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Pedodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. ***...

full text

Effect of conditioner on microtensile bond strength of self-adhesive resin cements to dentin.

OBJECTIVE Evaluate, in vitro, the microtensile bond strength (µTBS) of RelyX ARC conventional resin cement and RelyX Unicem and Maxcem self-adhesive resin cements to dentin, and the influence of polyacrylic acid pretreatment on the µTBS. MATERIAL AND METHODS Flat dentin surfaces were obtained in 15 third molars which were randomly divided into 5 groups: Group 1 - RelyX ARC (control); Group 2 ...

full text

My Resources

Save resource for easier access later


Journal title:
dental research journal

جلد ۱۳، شماره ۲، صفحات ۰-۰

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023