comparison of multiplex pcr-elisa and conventional multiplex pcr for detection of hiv-1/hcv co-infection
Authors
abstract
background and objectives: pcr is a sensitive assay and could be used as an accurate diagnostic method for detecting various types of microorganisms' genome in low concentration in biological specimens. the demand for sensitive, rapid, safe and easy detection of pcr products has led researchers to a combination of this method with elisa. materials and methods: conserved sequences were selected for design of primers. samples were tested by elisa (for detection of specific hiv and hcv proteins) and real- time pcr for detection of specific nucleic acid and viral genome respectively. viral genome was extracted and reverse transcription was performed with m-mulv and the cdna kept at -80º c. the pcr products were labeled by dig-dutp. diluted pcr products were analyzed with both electrophoresis and elisa methods. results: thirty-five samples were tested with the pcr-elisa method. false positive or negative reactions were not observed. elisa results of diluted products were compared with results obtained by electrophoresis. in gel electrophoresis, dilution of 1/10 was positive, but in elisa, optical density of 1/100 dilution was much more than the cut-off value. conclusion: detection limits for gel electrophoresis as well as elisa have been evaluated. it was shown that the pcr-elisa method is ten times more sensitive than conventional pcr.
similar resources
a novel sensitive multiplex rt-pcr elisa method for detection of hiv-1/hcv co-infection
objective: despite sensitive antibody based blood donor screening, infection can be transmitted during window period. therefore sensetive methods bosed on nucleic acid tests (nats) have been considered. the aim of this project was to design a more sensitive method for detection of pcr products and diagnosis of hiv-1/hcv co-infection accurately. materials and methods: after designing specific p...
full textComparison between conventional PCR and PCR - ELISA for detection of Brucella melitensis
Molecular detection techniques are believed to be key tools for both prevention and treatment follow up of brucellosis within live stock and human beings. Consequently rapid, reliable, easy to perform and automated systems for Brucella detection are urgently needed to allow early diagnosis and adequate antibiotic therapy in time. Brucellosis is a worldwide re-emerging zoonosis causing high econ...
full textComparing Rapid and Specific Detection of Brucella in Clinical Samples by PCR-ELISA and Multiplex-PCR Method
Background: Rapid diagnosis and differentiation of Brucella is of high importance due to the side effects of antibiotics for the treatment of brucellosis. This study aimed to identify and compare PCR-ELISA as a more accurate diagnositc test with other common molecular and serological tests. Methods: ...
full textComparison of Two Multiplex PCR Systems for Meat Species Authentication
Background: Meat species adulteration has become a problem of concern. This study aimed to compare two previously published multiplex Polymerase Chain Reaction (PCR) methods for meat species authentication. Methods: The primers used in the first multiplex PCR involved species-specific reverse primer for sheep, goat, cattle, pig, and donkey with universal forward primer. In the second multiple...
full textOptimization of PCR-ELISA in Detection of Human Cytomegalovirus Infection
Abstract Background and Objective: Human Cytomegalovirus (CMV) is an important cause of congenital viral infection that can lead to serious diseases and complications in infants. Application of rapid, sensitive, and specific HCMV detection methods is necessary for congenital infection detection. We aimed to optimize the use of PCR and ELISA for detection of HCMV in infants. Material and Methods...
full textValidation of multiplex PCR for detection and differentiation of Salmonellas
Methods The PCR-based detection technique for five Salmonella species was tested under O.I.E. requirements, to determine specificity, sensitivity, and repeatability. Primers were calculated by OLIGO software and produced with HPLC purification. Amplification was conducted by a T3000 Biometra PCR-machine. Testing was performed on a panel of five basic agents: Salmonella enterica ser. Enteritidis...
full textMy Resources
Save resource for easier access later
Journal title:
iranian journal of microbiologyجلد ۱، شماره ۴، صفحات ۳-۸
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023