study of different tissue density effects on the dose distribution of a 103pd brachytherapy source model med3633
Authors
abstract
introduction: clinical application of encapsulated radioactive brachytherapy sources has a major role in cancer treatment. in the present research, the effects of different tissue densities on the dose distribution of a 103pd brachytherapy source in a spherical phantom of 50 cm radius have been studied. material and methods: as is well known, absorbed dose in tissue depends to its density, but this difference is not clear in measurements. therefore, we applied the mcnp code to evaluate the effect of density on the dose distribution. 103pd brachytherapy sources are used to treat prostate, breast and other cancers. results: absorbed dose has been calculated and presented around a source placed in the center of the phantom for different tissue densities. also, we derived anisotropy and radial dose functions and compared our monte carlo results with experimental results of rivard and li et al. for f(1, θ) and g(r) in 1.040 g/cm3 tissue. conclusion: the results of this study show that relative dose variations around the source center are very considerable at different densities, because of the presence of a photoabsorber (au-cu alloy) in the source core. dose variation exceeds 80% at the point (z = 2.4 mm, y = 0 mm). computed values of anisotropy and radial dose functions are in good agreement with the experimental results of rivard and li et al.
similar resources
Study of Different Tissue Density Effects on the Dose Distribution of a 103Pd Brachytherapy Source Model MED3633
Introduction: Clinical application of encapsulated radioactive brachytherapy sources has a major role in cancer treatment. In the present research, the effects of different tissue densities on the dose distribution of a 103Pd brachytherapy source in a spherical phantom of 50 cm radius have been studied. Material and Methods: As is well known, absorbed dose in tissue depends to its density, but ...
full textthe effect of traffic density on the accident externality from driving the case study of tehran
در این پژوهش به بررسی اثر افزایش ترافیک بر روی تعداد تصادفات پرداخته شده است. به این منظور 30 تقاطع در شهر تهران بطور تصادفی انتخاب گردید و تعداد تصادفات ماهیانه در این تقاطعات در طول سالهای 89-90 از سازمان کنترل ترافیک شهر تهران استخراج گردید و با استفاده از مدل داده های تابلویی و نرم افزار eviews مدل خطی و درجه دوم تخمین زده شد و در نهایت این نتیجه حاصل شد که تقاطعات پر ترافیک تر تعداد تصادفا...
15 صفحه اولa study on insurer solvency by panel data model: the case of iranian insurance market
the aim of this thesis is an approach for assessing insurer’s solvency for iranian insurance companies. we use of economic data with both time series and cross-sectional variation, thus by using the panel data model will survey the insurer solvency.
a study on construction of iranian life tables: the case study of modified brass logit system
چکیده ندارد.
15 صفحه اولthe effect of consciousness raising (c-r) on the reduction of translational errors: a case study
در دوره های آموزش ترجمه استادان بیشتر سعی دارند دانشجویان را با انواع متون آشنا سازند، درحالی که کمتر به خطاهای مکرر آنان در متن ترجمه شده می پردازند. اهمیت تحقیق حاضر مبنی بر ارتکاب مکرر خطاهای ترجمانی حتی بعد از گذراندن دوره های تخصصی ترجمه از سوی دانشجویان است. هدف از آن تاکید بر خطاهای رایج میان دانشجویان مترجمی و کاهش این خطاها با افزایش آگاهی و هوشیاری دانشجویان از بروز آنها است.از آنجا ک...
15 صفحه اولA Monte Carlo Study on the Effect of Various Neutron Capturers on Dose Distribution in Brachytherapy with 252Cf Source
Background: In neutron interaction with matter and reduction of neutron energy due to multiple scatterings to the thermal energy range, increasing the probability of thermal neutron capture by neutron captures makes dose enhancement in the tumors loaded with these materials. Objective: The purpose of this study is to evaluate dose distribution in the presence of 10B, 157Gd and 33S neutron...
full textMy Resources
Save resource for easier access later
Journal title:
iranian journal of medical physicsجلد ۷، شماره ۳، صفحات ۵۵-۶۲
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023