monte carlo simulation for treatment planning optimization of the coms and usc eye plaques using the mcnp4c code
Authors
abstract
introduction: ophthalmic plaque radiotherapy using i-125 radioactive seeds in removable episcleral plaques is often used in management of ophthalmic tumors. radioactive seeds are fixed in a gold bowl-shaped plaque and the plaque is sutured to the scleral surface corresponding to the base of the intraocular tumor. this treatment allows for a localized radiation dose delivery to the tumor with a minimum target dose of 85 gy. the goal of this study was to develop a monte carlo simulation method for treatment planning optimization of the coms and usc eye plaques. material and methods: the mcnp4c code was used to simulate three plaques: coms-12mm, coms-20mm, and usc #9 with i-125 seeds. calculation of dose was performed in a spherical water phantom (radius 12 mm) using a 3d matrix with a size of 12 voxels in each dimension. each voxel contained a sphere of radius 1 mm. results: dose profiles were calculated for each plaque. isodose lines were created in 2 planes normal to the axes of the plaque, at the base of the tumor and at the level of the 85 gy isodose in a 7 day treatment. discussion and conclusion: this study shows that it is necessary to consider the following tumor properties in design or selection of an eye plaque: the diameter of tumor base, its thickness and geometric shape, and the tumor location with respect to normal critical structures. the plaque diameter is selected by considering the tumor diameter. tumor thickness is considered when selecting the seed parameters such as their number, activity and distribution. finally, tumor shape and its location control the design of following parameters: the shape and material of the plaque and the need for collimation.
similar resources
Monte Carlo Simulation for Treatment Planning Optimization of the COMS and USC Eye Plaques Using the MCNP4C Code
Introduction: Ophthalmic plaque radiotherapy using I-125 radioactive seeds in removable episcleral plaques is often used in management of ophthalmic tumors. Radioactive seeds are fixed in a gold bowl-shaped plaque and the plaque is sutured to the scleral surface corresponding to the base of the intraocular tumor. This treatment allows for a localized radiation dose delivery to the tumor with a ...
full textImproved treatment planning for COMS eye plaques.
PURPOSE A recent reanalysis of the Collaborative Ocular Melanoma Study (COMS) medium tumor trial concluded that incorporating factors to account for anisotropy, line source approximation, the gold plaque, and attenuation in the Silastic seed carrier into the dose calculations resulted in a significant and consistent reduction of calculated doses to structures of interest within the eye. The aut...
full textEvaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation
Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of...
full textMonte Carlo simulation of two 106Ru eye plaques in a new mathematical human eye model
BEBIG Ruthenium-106 ophthalmic plaques have been used for treatment of uveal melanoma, retinoblastoma, melanoma of the iris and other special applications for many years. The plaques consist of a thin film of 106Ru, a beta emitter, encapsulated in pure silver. The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new mod...
full textevaluation of the rtdoseplan treatment planning system using radiochromic film and monte carlo simulation
introduction: gafchromic ebt films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (tpss). their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. this study was designed to evaluate the dosimetric parameters of...
full textthe use of appropriate madm model for ranking the vendors of mci equipments using fuzzy approach
abstract nowadays, the science of decision making has been paid to more attention due to the complexity of the problems of suppliers selection. as known, one of the efficient tools in economic and human resources development is the extension of communication networks in developing countries. so, the proper selection of suppliers of tc equipments is of concern very much. in this study, a ...