applicator attenuation effect on dose calculations of esophageal high-dose rate brachytherapy using edr2 film
Authors
abstract
introduction interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. the effect of applicator attenuation is not considered in dose calculation method released by aapm-tg43. in this study, the effect of high-dose rate (hdr) brachytherapy esophageal applicator on dose distribution was surveyed in hdr brachytherapy. materials and methods a cylindrical pmma phantom was built in order to be inserted by various sizes of esophageal applicators. edr2 films were placed at 33 mm from ir-192 source and irradiated with 1.5 gy after planning using treatment planning system for all applicators. results the results of film dosimetry in reference point for 6, 8, 10, and 20 mm applicators were 1.54, 1.53, 1.48, and 1.50 gy, respectively. the difference between practical and treatment planning system results was 0.023 gy (<2.7%), on average. conclusion due to the similar practical results for different esophageal applicators, it can be concluded that attenuation properties of applicator wall doesn't have a significant difference with water and therefore the flexiplan treatment planning system accuracy is further confirmed.
similar resources
Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...
full textRadiochromic film dosimetry of rectal inhomogeneity and applicator attenuation in high dose rate brachytherapy of uterine cervix
Heterogeneities existing in the patient during treatment are neglected, as the treated subject is considered homogeneous in most of the commercially-available treatment planning systems (TPSs) used for high dose rate (HDR) brachytherapy. The choice of a suitable dosimeter for experimental dosimetry near the HDR source is crucial, mainly due to existence of steep dose gradients. The present work...
full textClinical implementation of a novel applicator in high-dose-rate brachytherapy treatment of esophageal cancer
PURPOSE In this study, we present the clinical implementation of a novel transoral balloon centering esophageal applicator (BCEA) and the initial clinical experience in high-dose-rate (HDR) brachytherapy treatment of esophageal cancer, using this applicator. MATERIAL AND METHODS Acceptance testing and commissioning of the BCEA were performed prior to clinical use. Full performance testing was...
full textQuality assurance measurements for high‐dose‐rate brachytherapy without film
The purpose of this study was to develop new and modified tools that allow HDR brachytherapy quality assurance tests to be carried out efficiently without film, video cameras, stopwatches, and mechanical rulers; and to devise methods that use these new tools for daily and quarterly check procedures, which are efficient and provide increased accuracy compared to previous methods. The HDR brachyt...
full textFractionated High-Dose-Rate Brachytherapy
Purpose: A growing body of data suggests that local control in nasopharyngeal cancer (NPC) is related to the radiation dose administered. We conducted a singleinstitution study of high-dose radiotherapy (RT), which incorporated high-dose-rate (HDR) brachytherapy (BT). These results were analyzed together with data obtained from controls who did not receive BT. Patients and Methods: The BT group...
full textMonte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources
Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two 60Co sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside ...
full textMy Resources
Save resource for easier access later
Journal title:
iranian journal of medical physicsجلد ۹، شماره ۱، صفحات ۱۹-۲۴
Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023