the monte carlo assessment of photon organ doses from 222rn progeny in adult ornl phantom

Authors

shila banari bahnamiri physics department, faculty of science, ferdowsi university of mashhad, mashhad, iran

abstract

introduction the potential hazards posed by exposure to radiation from radon have been of great concern worldwide, since it is especially associated with increased risk of lung cancer. some radioisotopes of radon progeny deposited in the human lungs emit β particles followed by the γ rays. while γ rays are comparatively less damaging to the respiratory system than α and β particles, it is the principal deposited energy in other organs. materials and methods in order to establish a quantitative estimate of hazards caused by the radiation, this paper studies the photon absorbed doses from radon progeny in all major organs of the human body through a simulation of the oak ridge national laboratory (ornl) adult phantom using mcnpx2.4.0 monte carlo code and calculations which were performed in photon/electron mode. results effective dose due to photons from radon progeny deposited in the human lungs was about 1.69 µsvwlm-1. based on unscear2006 reports, the effective dose of these photons per year is about 5.76´10-1msv  in for radon concentration of 31000 bq/m3  (the maximum concentration of radon in iran). therefore, this value is comparable with 1msv (the annual allowable effective dose). conclusion the dosimetry of photons particularly in areas with high levels of exposure to radon and radon's decay products is important because all organs receive the photon absorbed dose from radon progeny.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

The Monte Carlo Assessment of Photon Organ Doses from 222Rn Progeny in Adult ORNL Phantom

Introduction The potential hazards posed by exposure to radiation from radon have been of great concern worldwide, since it is especially associated with increased risk of lung cancer. Some radioisotopes of radon progeny deposited in the human lungs emit β particles followed by the γ rays. While γ rays are comparatively less damaging to the respiratory system than α and β particles, it is the p...

full text

Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA

Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV...

full text

Absorbed Dose Assessment from Short-Lived Radionuclides of Radon (222Rn) Decay Chain in Lung Tissue: A Monte Carlo Study

Introduction: Internal exposure to radon gas progeny can lead to serious biologic damages to the lung tissue. The aim of this study was to evaluate the absorbed dose by lung tissue due to the exposure from short-lived radioactive products of radon (222Rn) decay using Monte Carlo simulation. Material and Methods: A lung equivalent p...

full text

Calculating organ doses of patients in spiral CT using EGS 4 Monte - Carlo simulation of voxel phantom

According as the progress of medical technique, X-ray imaging systems have been progressed. Especially, X-ray CT imaging system have been improved and widely used as general diagnostic methods nowadays in Japan. However, the doses for patients of X-ray CT imaging are relatively higher than of other Xray examinations. The dose estimations and optimizations on X-ray CT are very important for medi...

full text

Comparison of Radon (222Rn) and Thoron (220Rn) Gamma Dosimetry in the Environment Using the ORNL Mathematical Phantom

Background: The potential hazards of exposure to radiation from radon have been of great concern worldwide, as it is associated with an increased risk of lung cancer. Radon (222Rn) and its progeny are the main sources of radioactivity in the environment. The half-life of 222Rn (3.82 days) is long enough for it to diffuse into and build up in homes. 220Rn or thoron from the 232Th series, and 219...

full text

Effects of Human Model Configuration in Monte Carlo Calculations on Organ Doses from CT Examinations

1 Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Ibaraki, 319-1195, Japan 2 Oita Prefecture-Mie Hospital, 3964-1 Miemachi-Miyano, Bungoono-shi, Oita, 879-7101, Japan 3 Shin-Beppu Hospital, 3898 Tsurumi, Beppu-shi, Oita, 874-0833, Japan 4 Tokai University Oiso Hospital, 21-1 Gakkyou, Oiso-machi, Kanagawa, 259-0198, Japan 5 Tokai University Hospital, 143 Shimokasuya, Isehara-shi, Kanagawa...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of medical physics

جلد ۹، شماره ۲، صفحات ۹۳-۱۰۲

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023