step-and-shoot versus compensator-based imrt: calculation and comparison of integral dose in non-tumoral and target organs in prostate cancer
Authors
abstract
introduction intensity-modulated radiotherapy (imrt) is becoming an increasingly routine treatment method. imrt can be delivered by use of conventional multileaf collimators (mlcs) and/or physical compensators. one of the most important factors in selecting an appropriate imrt technique is integral dose. integral dose is equal to the mean energy deposited in the total irradiated volume of the patient. the aim of the present study was to calculate and compare the integral dose in normal and target organs in two different procedures of imrt: step-and-shoot (sas) and compensator-based imrt. materials and methods in this comparative study, five patients with prostate cancer were selected. module integrated radiotherapy system was applied, using three energy ranges. in both treatment planning methods, the integral dose dramatically decreased by increasing energy. results comparison of two treatment methods showed that on average, the integral dose of body in sas radiation therapy was about 1.62% lower than that reported in compensator-based imrt. in planning target volume, rectum, bladder, and left and right femoral heads, the integral doses for sas method were 1.01%, 1.02%, 1.11%, 1.47%, and 1.40% lower than compensator-based imrt, respectively. conclusion considering the treatment conditions, the definition of dose volume constraints for healthy tissues, and the equal volume of organs in both treatment methods, sas radiation therapy by providing a lower integral dose seems to be more advantageous and efficient for prostate cancer treatment, compared to compensator-based imrt.
similar resources
Step-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer
Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...
full textpatterns and variations in native and non-native interlanguage pragmatic rating: effects of rater training, intercultural proficiency, and self-assessment
although there are studies on pragmatic assessment, to date, literature has been almost silent about native and non-native english raters’ criteria for the assessment of efl learners’ pragmatic performance. focusing on this topic, this study pursued four purposes. the first one was to find criteria for rating the speech acts of apology and refusal in l2 by native and non-native english teachers...
15 صفحه اولAssessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer
Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...
full textassessment of deep word knowledge in elementary and advanced iranian efl learners: a comparison of selective and productive wat tasks
testing plays a vital role in any language teaching program. it allows teachers and stakeholders, including program administrators, parents, admissions officers and prospective employers to be assured that the learners are progressing according to an accepted standard (douglas, 2010). the problems currently facing language testers have both practical and theoretical implications but the first i...
a corpus-based study of the frequency of personal pronouns in translated and comparable non-translated persian texts
چکیده ندارد.
15 صفحه اولComparison of dosimetric and radiobiological effects of various IMRT techniques regarding to joint volume between target tissue and organs at risk in prostate cancer patients
Background: Intensity-modulated radiotherapy (IMRT) is one of the most usable methods in prostate radiotherapy that is used with different techniques. The aim of this study was to evaluate and compare the dosimetric and radiobiological effects of prostate IMRT techniques regarding to joint volume between the target tissue and organs at risk as a patients anatomical parameter. Methods: This res...
full textMy Resources
Save resource for easier access later
Journal title:
iranian journal of medical physicsجلد ۱۲، شماره ۱، صفحات ۶۲-۶۹
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023