dose calculations for lung inhomogeneity in high-energy photon beams and small beamlets: a comparison between xio and tigrt treatment planning systems and mcnpx monte carlo code
Authors
abstract
introduction radiotherapy with small fields is used widely in newly developed techniques. additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. in the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against monte carlo method. materials and methods siemens once or linear accelerator was simulated, using mcnpx monte carlo code, according to manufacturer’s instructions. three analytical algorithms for dose calculation including full scatter convolution (fsc) in tigrt, along with convolution and superposition in xio system were evaluated for a small solid liver tumor. this solid tumor with a diameter of 1.8 cm was evaluated in a thorax phantom, and calculations were performed for different field sizes (1×1, 2×2, 3×3 and4×4 cm2). the results obtained in these treatment planning systems were compared with calculations by mc method (regarded as the most reliable method). results for fsc and convolution algorithm, comparison with mc calculations indicated dose overestimations of up to 120%and 25% inside the lung and tumor, respectively in 1×1 cm2field size, using an 18 mv photon beam. regarding superposition, a close agreement was seen with mc simulation in all studied field sizes. conclusion the obtained results showed that fsc and convolution algorithm significantly overestimated doses of the lung and solid tumor; therefore, significant errors could arise in treatment plans of lung region, thus affecting the treatment outcomes. therefore, use of mc-based methods and super position is recommended for lung treatments, using small fields and beamlets.
similar resources
Dose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code
Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...
full textDose calculations accuracy of TiGRT treatment planning system for small IMRT beamlets in heterogeneous lung phantom
Background: Accurate dose calculations in small beamlets and lung material have been a great challenge for most of treatment planning systems (TPS). In the current study, the dose calculation accuracy of TiGRT TPS was evaluated for small beamlets in water and lung phantom by comparison to Monte Carlo (MC) calculations. Materials and Methods: The head of Siemens Oncor-impression linac...
full textDose calculations accuracy of TiGRT treatment planning system for small IMRT beamlets in heterogeneous lung phantom
Background: Accurate dose calcula ons in small beamlets and lung material have been a great challenge for most of treatment planning systems (TPS). In the current study, the dose calcula on accuracy of TiGRT TPS was evaluated for small beamlets in water and lung phantom by comparison to Monte Carlo (MC) calcula ons. Materials and Methods: The head of Siemens Oncorimpression linac was simulated ...
full textComparison and Evaluation of the Effects of Rib and Lung Inhomogeneities on Lung Dose in Breast Brachytherapy using a Treatment Planning System and the MCNPX Code
Introduction: This study investigates to what extent the computed dose received by lung tissue in a commercially available treatment planning system (TPS) for 192Ir high-dose-rate breast brachytherapy is accurate in view of tissue inhomogeneities and presence of ribs. Materials and Methods: A CT scan of the breast was used to construct a patient-equivalent phantom in the clinical treatment plan...
full textDPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations.
A new Monte Carlo (MC) algorithm, the 'dose planning method' (DPM), and its associated computer program for simulating the transport of electrons and photons in radiotherapy class problems employing primary electron beams, is presented. DPM is intended to be a high accuracy MC alternative to the current generation of treatment planning codes which rely on analytical algorithms based on an appro...
full textThe effect of electronic disequilibrium on the received dose by lung in small fields with photon beams: Measurements and Monte Carlo study
Background: Prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. Application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. To study the lung absorbed dose in radiotherapy with smal...
full textMy Resources
Save resource for easier access later
Journal title:
iranian journal of medical physicsجلد ۱۲، شماره ۳، صفحات ۱۶۷-۱۷۷
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023