esophageal cancer is the eighth most ordinary cancer and the sixth most common cancer between the males and ninth for females in the world; its major and effective treatment is external radiotherapy. this type of cancer can be found in different areas of esophagus including cervical, upper, middle and lower esophagus. in this treatment, healthy tissues such as the trachea, spine and sternum and even thyroid receive dose and it is important that the absorbed doses by these organs be in their tolerance dose levels. we measured the surface and depth doses in an anthropomorphic phantom using thermoluminescent dosimeters. to do so, a target volume was considered in the phantom as a primary esophageal tumor with margins of 5 cm in the distal and proximal, and 3 cm in lateral. phantom was ct planned and treatment was performed according to patient treatment. the considered measurement locations were eye, right and left parotid, left and right submandibular, left and right thyroid, trachea, manubrium of sternum and spine. our results show that in places located further to primary beam such as thyroid (phase one), trachea, spine and sternum, the difference between dose from tps and tld measurements is observed. in organs which have placed within scattered radiation, the difference is insignificant (p-value≥0.05), although some differences might cause by tld limitations. in conclusion, the tps calculated and tl measured doses distinguish significantly at the spine (depth), trachea (depth) and manubrium of sternum especially in phase 1 which might be due to the calculation algorithm used by the planning system which is reliable in homogeneous medium, but tl measurements were performed in the heterogeneous anthropomorphic phantom.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Image guidance during breast radiotherapy: a phantom dosimetry and radiation-induced second cancer risk study

Imaging procedures utilised for patient position verification during breast radiotherapy can add a considerable dose to organs surrounding the target volume on top of therapeutic scatter dose. This study investigated the dose from a breast kilovoltage cone-beam CT (kV-CBCT), a breast megavoltage fan-beam CT (MV-FBCT), and a TomoDirect breast treatment. Thermoluminescent dosimeters placed within...

full text

Comparing the results of 3D treatment planning and practical dosimetry in craniospinal radiotherapy using Rando phantom

Background: Craniospinal radiotherapy faces technical challenges which are due to the sensitivity of the location in which the gross tumor is, and to organs at risk around planning target volume. Using modern treatment planning systems causes a reduction in the complexities of the treatment techniques. The most effective method to assess the dosimetric accuracy and the validity of the ...

full text

Study of a spherical phantom for Gamma knife dosimetry

Four 16 cm diameter spherical phantoms were modeled in this study: a homogenous water phantom, and three water phantoms with 1 cm thick shell each made of different materials (PMMA, Plastic WaterTM and polystyrene). The PENELOPE Monte Carlo code was utilized to simulate photon beams from the Leksell Gamma Knife (LGK) unit and to determine absorbed dose to water (Dw) from a single 18 mm beam del...

full text

Dose verification of radiotherapy for lung cancer by using plastic scintillator dosimetry and a heterogeneous phantom

Bone, air passages, cavities, and lung are elements present in patients, but challenging to properly correct for in treatment planning dose calculations. Plastic scintillator detectors (PSDs) have proven to be well suited for dosimetry in non-reference conditions such as small fields. The objective of this study was to investigate the performance of a commercial treatment planning system (TPS) ...

full text

a study of translation of english litrary terms into persian

چکیده هدف از پژوهش حاضر بررسی ترجمه ی واژه های تخصصی حوزه ی ادبیات به منظور کاوش در زمینه ی ترجمه پذیری آنها و نیز راهکار های به کار رفته توسط سه مترجم فارسی زبان :سیامک بابایی(1386)، سیما داد(1378)،و سعید سبزیان(1384) است. هدف دیگر این مطالعه تحقیق در مورد روش های واژه سازی به کار رفته در ارائه معادل های فارسی واژه های ادبی می باشد. در راستای این اهداف،چارچوب نظری این پژوهش راهکارهای ترجمه ار...

15 صفحه اول

Comparing the results of 3D treatment planning and practical dosimetry in craniospinal radiotherapy using Rando phantom

1Radiation Medicine Department, Nuclear Engineering Faculty, Shahid Beheshti University, Tehran, Iran 2Radiation Medicine Department, Nuclear Engineering Faculty, Shahid Beheshti University, Tehran, Iran 3Radiotherapy Physics Department, Cancer Institute of Tehran, Tehran, Iran 4Medical Physics Department, Medical Faculty, Iran University of Medical Science, Tehran, Iran 5Radiation Medicine Dep...

full text

My Resources

Save resource for easier access later


Journal title:
journal of paramedical sciences

جلد ۵، شماره ۳، صفحات ۰-۰

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023