a comparison between the raypex5 apex locator and conventional radiography for determining working length of straight and curved canals

Authors

shiva sadeghi department of endodontics, dental school, guilan university of medical sciences, rasht, iran

masoomeh abolghasemi private practice, rasht, iran

abstract

introduction: the purpose of this in vitro study was to compare the accuracy of the new electronic apex locator raypex5 with radiography for working length determination of straight and curved root canals. materials and methods: twenty straight and single canals of maxillary central teeth and twenty curved mesiobuccal canals of mandibular molar teeth were used. access cavities were prepared and working lengths were determined by means of raypex5 and conventional radiography then compared with actual working lengths (awl). data were analyzed by anova with repeated measurements and least significant difference (lsd) test. results: there was no significant difference between electronic and actual working length determination for straight canals (p=0.74). for curved canals the difference between electronic and actual working length was significant (p<0.0001). there was a significant difference between radiographic and actual working length determination either for straight and curved canals (p=0.024, p<0.0001). the difference between radiographic and electronic working length determination was also significant for straight canals (p=0.006). the percentage of electronic measurements within ±0.5 of awl was 70% for straight canals and 35% for curved root canals. the percentage of radiographic measurements within ± 0.5 of awl was 50% for straight canals and 25% for curved root canals. conclusion: raypex 5 is an apex locator that measured the tooth length within a clinically acceptable range especially in anterior straight canals.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study

Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...

full text

comparison of working length determination using apex locator and conventional radiography in curved canals-an in vitro study

introduction: the exact measurement of the root canal length is of great importance in root canal therapy. although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. the purpose of this study was to compare the accuracy of an electronic apex l...

full text

evaluation of conventional radiography and an electronic apex locator in determining the working length in c-shaped canals

introduction: the purpose of this in vitro study was to compare the accuracy of working length determination using the apex locator versus conventional radiography in c-shaped canals. methods and materials: after confirming the actual c-shaped anatomy using cone-beam computed tomography (cbct), 22 extracted c-shaped mandibular second molars were selected and decoronated at the cemento-enamel ju...

full text

Evaluation of Conventional Radiography and an Electronic Apex Locator in Determining the Working Length in C-shaped Canals

INTRODUCTION The purpose of this in vitro study was to compare the accuracy of working length determination using the apex locator versus conventional radiography in C-shaped canals. METHODS AND MATERIALS After confirming the actual C-shaped anatomy using cone-beam computed tomography (CBCT), 22 extracted C-shaped mandibular second molars were selected and decoronated at the cemento-enamel ju...

full text

Comparison of working length determination using apex locator, conventional radiography and radiovisiography: an in vitro study.

AIM The purpose of this study was to compare the working length determination done using three methods, namely, apex locator (Foramatron D-10, Parkell), radiovisiography (Planmeca) and conventional radiography (Prostyle intra, Planmeca). MATERIALS AND METHODS In this experiment, to determine the working length, 35 single-rooted teeth were selected and each tooth was subjected to all the three...

full text

comparison between the accuracy of digital and conventional radiographies for evaluation of the curved canals length

introduction proper cleaning and shaping of the root canal system is one of the most important aspects of endodontic therapy. to estimate the canal length before instrumentation in endodontic treatment, traditionally, conventional radiographic techniques and, recently, direct digital radiography (ddr) are applied. the application of computer technology in radiography has allowed less exposure t...

full text

My Resources

Save resource for easier access later


Journal title:
iranian endodontic journal

جلد ۲، شماره ۳، صفحات ۱۰۱-۱۰۴

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023