comparison of diffuse weighted imaging and fluid attenuation inversion recovery sequences of mri in brain multiple sclerosis plaques detection

Authors

reza nafisi-moghadam radiologist , associate professor , department of radiology, shahid sadoughi university of medical sciences, yazd, iran

abolghasem rahimdel neurologist, assistant professor, department of neurology, shahid sadoughi university of medical sciences, yazd, iran

tahereh shanbeh-zadeh general physician

razieh fallah pediatric neurologist, associate professor, department of pediatrics, growth disorders of children research center , shahid sadoughi university of medical sciences, yazd, iran

abstract

purpose: suitable magnetic resonance imaging (mri) techniques from conventional to new devices can help physicians in diagnosis and follow up of multiple sclerosis (ms) patients. the aim of present research was to compare effectiveness of fluid attenuation inversion recovery (flair) sequence of conventional mri and diffuse weighted imaging (dwi) sequence as a new technique in detection of brain ms plaques. methods : in an analytic cross sectional study, dwi and flair sequences of without contrast brain mri of consecutive ms patients whom were referred to mri center of shahid sadoughi hospital, yazd, iran from january to may 2012, evaluated. results: 32 females and 8 males with mean age of 35.20±9.80 years (range = 11-66 years) were evaluated and finally 340 plaques including 127(37.2%) in t2wi, 127(37.2%) in flair, 63(18.5%) in dwi and 24(7.1%) in t1wi were detected. flair sequence is more efficient than dwi in detection of brain ms plaques, oval, round and amorphous plaque shapes, frontal and occipital lobes, periventricular, intracapsular, corpus callosum, centrum semiovale, subcortical and basal ganglia plaques and diameter of detected ms plaques in dwi sequence is smaller than in flair. conclusion: old lesion can be detected by conventional mri and new techniques might be more useful in early inflammatory phase of ms and assessment of experimental treatments. other next studies with more sample size, evaluation and comparison of different mri techniques and in different stages of the disease might be useful for selection of more suitable mri protocols in detection of ms plaques.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Comparison of Diffuse Weighted Imaging and Fluid Attenuation Inversion Recovery Sequences of MRI in Brain Multiple Sclerosis Plaques Detection

OBJECTIVE Suitable magnetic resonance imaging (MRI) techniques from conventional to new devices can help physicians in diagnosis and follow up of Multiple Sclerosis (MS) patients. The aim of present research was to compare effectiveness of Fluid Attenuation Inversion Recovery (FLAIR) sequence of conventional MRI and Diffuse Weighted Imaging (DWI) sequence as a new technique in detection of brai...

full text

The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques

Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...

full text

investigation of single-user and multi-user detection methods in mc-cdma systems and comparison of their performances

در این پایان نامه به بررسی روش های آشکارسازی در سیستم های mc-cdma می پردازیم. با توجه به ماهیت آشکارسازی در این سیستم ها، تکنیک های آشکارسازی را می توان به دو دسته ی اصلی تقسیم نمود: آشکارسازی سیگنال ارسالی یک کاربر مطلوب بدون در نظر گرفتن اطلاعاتی در مورد سایر کاربران تداخل کننده که از آن ها به عنوان آشکارساز های تک کاربره یاد می شود و همچنین آشکارسازی سیگنال ارسالی همه ی کاربران فعال موجود در...

Double inversion recovery brain imaging at 3T: diagnostic value in the detection of multiple sclerosis lesions.

BACKGROUND AND PURPOSE To prospectively determine the sensitivity in the detection of multiple sclerosis (MS) lesions by using double inversion recovery (DIR), fluid-attenuated inversion recovery (FLAIR), and T2-weighted turbo spin-echo (T2 TSE) MR imaging at 3T. METHODS Seventeen patients presenting with a clinically isolated syndrome (CIS) suggestive of MS, 9 patients with definite MS, and ...

full text

Synthetic MRI in the Detection of Multiple Sclerosis Plaques.

BACKGROUND AND PURPOSE Synthetic MR imaging enables the creation of various contrast-weighted images including double inversion recovery and phase-sensitive inversion recovery from a single MR imaging quantification scan. Here, we assessed whether synthetic MR imaging is suitable for detecting MS plaques. MATERIALS AND METHODS Quantitative and conventional MR imaging data on 12 patients with ...

full text

the optimization of magnetic resonance imaging pulse sequences in order to better detection of multiple sclerosis plaques

background and objective: magnetic resonance imaging (mri) is the most sensitive technique to detect multiple sclerosis (ms) plaques in central nervous system. in some cases, the patients who were suspected to ms, whereas mri images are normal, but whether patients don’t have ms plaques or mri images are not enough optimized enough in order to show ms plaques? the aim of the current study is ev...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of child neurology

جلد ۱۱، شماره ۱، صفحات ۰-۰

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023