the perceptibility curve test applied to ccd and two methods of digitization of dental film-based radiographs

Authors

s. nikneshan dept. of oral & maxillofacial radiology, school of dentistry, shahid beheshti university of medical sciences, tehran, iran.

b. moghaddamzade

abstract

objective: after introduction of digital radiography into dentistry several methods of image acquisition were accessible in the field of dentistry. in many instances it is necessary to digitize analog images. there is no overall acceptable method for image digitization so all different types of images can be comparable. the objective of this study was to compare the diagnostic accuracy of different methods of image digitization. methods: this study was an accuracy diagnostic test study. in current study perceptibility curve test which first introduced by de balder was applied. in this test a test object is used which is usually made by aluminum. different levels of thickness are necessary and there are a number of holes in the test object to have different levels of contrast. images from film and ccd and digitized images by means of ccd scanners and digital camera were prepared. nine observers assessed the images. data collected from observers delivered to spss software (spss 13.0, chicago, il) and for each image acquisition method interclass correlation coefficience (icc) was computed and compared to the gold standard. results: mean sensitivity, specifity, positive and negative like hood ratios in dependence on material thickness (steps) and the background gray value were calculated. in regions of high optical density (dark images, low gray value in background) the sensitivity for the film images was highest (0.994) following by ccd (0.905), scanner (0.889) and camera (0.821). difference between ccd images and scanner images was not significant. (p >0.05) in dark regions of no dark holes the sensitivity was highest for film images (0.832) following by ccd (0.798), camera (0.714) and scanner (0.615) difference between film and ccd images was not significant. (p >0.05). conclusion: the diagnostic quality of radiographic films was better than digital ccd sensors. and for digitizing analog images scanners are better than digital cameras.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

The perceptibility curve test applied to CCD and two methods of digitization of dental film-based radiographs

Objectives: Several methods of image acquisition are accessible in dentistry. There is no overall acceptable method for image digitization so all different types of images can be comparable. The objective of this study was to compare the diagnostic accuracy of different methods of image digitization. Methods: This accuracy diagnostic test study used perceptibility curve test which first intr...

full text

a synchronic and diachronic approach to the change route of address terms in the two recent centuries of persian language

terms of address as an important linguistics items provide valuable information about the interlocutors, their relationship and their circumstances. this study was done to investigate the change route of persian address terms in the two recent centuries including three historical periods of qajar, pahlavi and after the islamic revolution. data were extracted from a corpus consisting 24 novels w...

15 صفحه اول

construction and validation of the translation teacher competency test and the scale of students’ perceptions of translation teachers

the major purpose of this study was to develop the translation teacher competency test (ttct) and examine its construct and predictive validity. the present study was conducted in two phases: a qualitative phase as well as a quantitative phase. in the first phase of the study, the author attempted to find out the major areas of competency required for an academic translation teacher. the second...

a case study of the two translators of the holy quran: tahereh saffarzadeh and laleh bakhtiar

بطورکلی، کتاب های مقدسی همچون قران کریم را خوانندگان میتوان مطابق با پیش زمینه های مختلفی که درند درک کنند. محقق تلاش کرده نقش پیش زمینه اجتماعی-فرهنگی را روی ایدئولوژی های مترجمین زن و در نتیجه تاثیراتش را روی خواندن و ترجمه آیات قرآن کریم بررسی کند و ببیند که آیا تفاوت های واژگانی عمده ای میان این مترجمین وجود دارد یا نه. به این منظور، ترجمه 24 آیه از آیات قرآن کریم مورد بررسی مقایسه ای قرار ...

15 صفحه اول

My Resources

Save resource for easier access later


Journal title:
journal of dental school, shahid beheshti university of medical sciences

جلد ۳۴، شماره ۱، صفحات ۴۴-۵۰

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023