comparison of lead and cerrobend blocks for incident photon flux of 6 and 15 mv x-rays
Authors
abstract
background: during radiotherapy treatment, critical organs are shielded using lead and cerrobend blocks. the objective of this study is to compare the effects of lead and cerrobend shielding blocks on incident photon beam. methods: collimator scatter factors were measured for open square fields (3 x 3 cm to 40 x 40 cm) defined by collimator jaws and for fields blocked down to smaller asymmetric fields by using five different lead and cerrobend blocks for 6 and 15 mv photon beams from a varian clinac 2100c accelerator. the measurements in air were performed using farmer type ionization chamber fitted with acrylic build up caps. results: the block tray factor (btf) increased with field size for both 6 and 15 mv photon beams. in case of lead blocks, the extreme variations in btf for 6 mv photon beam are 0.70 %, 0.84 %, 0.56%, 0.80 % and 1.15 %. similarly, for 15 mv the maximum variations for lead blocks are 0.46 %, 0.60 %, 0.83 %, 0.88 % and 1.10 % respectively. no significant difference has been observed in the btf of cerrobend blocks for 6 and 15 mv photon beams. discussion: the dose received by a point in air apparently shielded by lead blocks has three main contributions: 1. due to primary photon beam transmitted through the block, 2. due to scattered photons, 3. due to contamination electrons. these three factors collectively cause the increase in btf with increasing field size, energy, and decreasing block size. conclusions: the effect of shielding on the beam output increases with field size, beam energy and shield size. this increase follows almost the same pattern for both lead and cerrobend shielding blocks. therefore shield factors for all field sizes, beam energies and shield sizes should be determined separately for precise patient dose delivery.
similar resources
comparison of zoe and vitapex for canal treatment of necrotic primary teeth
چکیده ندارد.
15 صفحه اولEvaluation of CorePlanTM treatment planning system for 6 and 15 MV photon irradiation
Introduction: Radiotherapy is an effective modality to treat esophageal carcinoma. Due to various inhomogenous tissues with a variety of physical and radiological properties which can cause uncertainty in accurate dose calculations in radiation therapy, accuracy of TPS is very important. The aim of this study was to quantify dose calculation accuracy of CoreplanTM TPS in an inh...
full textComparison between Clinically Used Irregular Fields Shielded by Cerrobend and Standard Lead Blocks
Introduction: In radiation therapy centers across Iran, protection of normal tissues is usually accomplished by either Cerrobend or lead block shielding. In this study, the influence of these two shielding methods on central axis dose distribution of photon beam a Cobalt unit was investigated in clinical conditions. Materials and Methods: All measurements were performed for 60Co γ-ray beams an...
full textassessment of deep word knowledge in elementary and advanced iranian efl learners: a comparison of selective and productive wat tasks
testing plays a vital role in any language teaching program. it allows teachers and stakeholders, including program administrators, parents, admissions officers and prospective employers to be assured that the learners are progressing according to an accepted standard (douglas, 2010). the problems currently facing language testers have both practical and theoretical implications but the first i...
a comparison of linguistic and pragmatic knowledge: a case of iranian learners of english
در این تحقیق دانش زبانشناسی و کاربردشناسی زبان آموزان ایرانی در سطح بالای متوسط مقایسه شد. 50 دانش آموز با سابقه آموزشی مشابه از شش آموزشگاه زبان مختلف در دو آزمون دانش زبانشناسی و آزمون دانش گفتار شناسی زبان انگلیسی شرکت کردند که سوالات هر دو تست توسط محقق تهیه شده بود. همچنین در این تحقیق کارایی کتابهای آموزشی زبان در فراهم آوردن درون داد کافی برای زبان آموزان ایرانی به عنوان هدف جانبی تحقیق ...
15 صفحه اولPreparation and characterization of Epoxy/Lead oxide nano-composite for shield against gamma and X-rays
Polymer nano-composites are a group of materials that represent proper mechanical, chemical, thermal and optical properties due to the presence of certain percentages of a filler in a polymeric matrix. In this study lead oxide nanoparticles were prepared by direct precipitation method. Then the lead oxide-epoxy resin nanocomposite was prepared by mixing (without solvent) with different weight p...
full textMy Resources
Save resource for easier access later
Journal title:
iranian journal of cancer preventionجلد ۴، شماره ۱، صفحات ۱۰-۱۴
Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023