development and validation of a hplc method for determination of pefloxacin in tablet and human plasma
Authors
abstract
objective(s) developing and validating a simple, efficient, reproducible and economic reversed phase high performance liquid chromatographic (rp-hplc) method for the quantitative determination of pefloxacin in bulk material, tablets and in human plasma. materials and methods a shim-pack clc-ods column and a mobile phase constituting acetonitrile: 0.025 m phosphoric acid solution (13:87 v/v, ph 2.9 adjusted with koh) were used. the flow rate was 1 ml/min and the analyses performed using ultraviolet (uv) detector at a wavelength of 275 nm using acetaminophen as an internal standard. results the developed method showed good resolution between pefloxacin and acetaminophen. it was selective to pefloxacin and able to resolve the drug peak from internal standard and from formulation excipients. the percentage of coefficient variation (cv) of the retention times and peak areas of pefloxacin from the six consecutive injections were 0.566% and 0.989%, respectively. the results showed that the peak area responses are linear within the concentration range of 0.125 qg/ml-12 qg/ml (r2= 0.9987). the limits of detection (lod) and limits of quantitation (loq) for pefloxacin were 0.03125 qg/ml and 0.125 qg/ml. the intra-day and inter-day variation, rsd were 0.376-0.9056 and 0.739-0.853 respectively; also, inter-day variation with relative standard deviation (rsd) were 0.1465-0.821 in plasma. the accuracy results of 70%, 100%, and 130% drugs were 100.72%, 100.34%, and 100.09%, respectively. conclusion the method is linear, quantitative, reproducible and could be used as a more convenient, efficient and economical method for the trace analysis of drug in biological fluids, in raw material and tablets.
similar resources
Development and Validation of a HPLC Method for Determination of Pefloxacin in Tablet and Human Plasma
Objective(s) Developing and validating a simple, efficient, reproducible and economic reversed phase high performance liquid chromatographic (RP-HPLC) method for the quantitative determination of pefloxacin in bulk material, tablets and in human plasma. Materials and Methods A shim-pack CLC-ODS column and a mobile phase constituting acetonitrile: 0.025 M phosphoric acid solution (13:87 v/v, ...
full textDevelopment and validation of a HPLC-UV method for determination of Proscillaridin A in Drimia maritima
Background and objectives:Drimia maritima (L.) Stearn also known as squill is a medicinally important plant that has been used for various ailments such as dropsy, respiratory disorders, jaundice and epilepsy from ancient times. Proscillaridin A is identified as one of the most effective compounds in the plant with remarkable pharmacological features including efficacy...
full textDevelopment and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples
Objective(s):The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v) at the flow...
full textthe innovation of a statistical model to estimate dependable rainfall (dr) and develop it for determination and classification of drought and wet years of iran
آب حاصل از بارش منبع تأمین نیازهای بی شمار جانداران به ویژه انسان است و هرگونه کاهش در کم و کیف آن مستقیماً حیات موجودات زنده را تحت تأثیر منفی قرار می دهد. نوسان سال به سال بارش از ویژگی های اساسی و بسیار مهم بارش های سالانه ایران محسوب می شود که آثار زیان بار آن در تمام عرصه های اقتصادی، اجتماعی و حتی سیاسی- امنیتی به نحوی منعکس می شود. چون میزان آب ناشی از بارش یکی از مولفه های اصلی برنامه ...
15 صفحه اولDevelopment and Validation of an HPLC Method for Determination of Amifostine and/or Its Metabolite (WR-1065) In Human Plasma Using OPA Derivatization and UV Detection
A rapid, sensitive and reproducible HPLC method was developed and validatedfor the analysis of amifostine (AMF) and/or its metabolite, WR-1065 inhuman plasma. The method involves the alkylation of free sulfydryl group with iodoacetic acid followed by derivatization of the drug and its metabolite witho-phthaldialdehyde (OPA) andUVdetection at 340 nm. The derivatized AMF and WR-1065 were eluted i...
full textDevelopment and Validation of an HPLC Method for Determination of Amifostine and/or Its Metabolite (WR-1065) In Human Plasma Using OPA Derivatization and UV Detection
A rapid, sensitive and reproducible HPLC method was developed and validatedfor the analysis of amifostine (AMF) and/or its metabolite, WR-1065 inhuman plasma. The method involves the alkylation of free sulfydryl group with iodoacetic acid followed by derivatization of the drug and its metabolite witho-phthaldialdehyde (OPA) andUVdetection at 340 nm. The derivatized AMF and WR-1065 were eluted i...
full textMy Resources
Save resource for easier access later
Journal title:
iranian journal of basic medical sciencesجلد ۱۲، شماره ۱، صفحات ۳۳-۴۲
Hosted on Doprax cloud platform doprax.com