assessment of correlation of left ventricular diastolic functional indices between gated myocardial perfusion spect and echocardiography

Authors

lida peivandi zahedan university of medical sciences, zahedan, iran; zahedan university of medical sciences, zahedan, iran

vahid reza dabbagh kakhki mashhad university of medical sciences, mashhad, iran

abstract

conclusions in this study there is no correlation between the main lv diastolic indices derived by spect and echocardiography, may be due to the main changes in the last version of guidline for assessment of lv diastolic function by echocardiography. results the population study consisted of 19 male and 30 female with the average age of 58.2 years.there is a mild negative correlation between pfr, mfr/3 and pfr/2 with la volume, la diameter and la index. there is a mild negative correlation between mfr/3 and posterior wall thickness and also a mild positive correlation between pfr/2 and systolic lv diameter. there is no significant correlation between spect diastolic indices with other variables in echocardiography. methods forty-nine consecutive patients referred to ghaem hospital, nuclear medicine ward, between 2013 to 2016, were performing both spect and echocardiography. diastolic lv indices in spect were calculated with qgs software and all data were recorded in spss for statistical analysis by performing correlation studies. p value less than 0.05 is defined as significant level. background left ventricular diastolic function assumes as a major morbidity and mortality risk factor in cardio-vascular diseases especially in patients with heart failure with preserved ejection fraction. in myocardial gated perfusion spect, both the perfusion and the lv function, specialy systolic ones, are evaluated. though diastolic indices, assessed by spect, are often overlooked in reports and they were not compared with the known methods for assessment of lv diastolic function, best of them is echocardiography (doppler and 2d). the aim of this study was to assess the correlation of lv diastolic indices with echocardiography.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography

Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...

full text

Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

full text

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

full text

normal values of left ventricular functional indices in gated 99mtc-mibi myocardial perfusion spect

introduction: although left ventricular(lv) function parameters measured by gated myocardial perfusion spect (gspect) have been validated, experimental data have revealed that the calculated the lv function parameters using gspect are affected by patient populations as well as particular acquisition and processing conditions. we tried to determine the normal values of gspect in an iranian popul...

full text

Normal Values of Left Ventricular Functional indices in Gated Tc-MIBI Myocardial Perfusion SPECT

Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values of GSPECT in an Iranian popul...

full text

Perfusion SPECT: Left Ventricular Function Indices and Myocardial Perfusion Findings

Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studied with post-stress and rest T...

full text