sentinel lymph node biopsy in melanoma patients: an experience with tc-99m antimony sulfide colloid

Authors

mostafa mehrabibahar

mohammad naser forghani

bahram memar

ali jangjoo

vahid reza dabbagh kakhki

abstract

introduction: sentinel lymph node biopsy is the standard procedure for lymph node staging in intermediate thickness melanoma. in iran, this procedure has not been addressed sufficiently. in this study, we report our experience in this area. methods: ten consecutive patients with intermediate thickness melanoma where included in our study. 1.5 mci of tc-99m antimony sulfide colloid in two divided dose was injected around the tumor. all patients underwent surgery 2-4 hours after injection of the tracer. patent blue v dye was also used for 8 patients. using a hand-held gamma probe, the sentinel nodes were harvested and sent to the pathologist for frozen section and h&e review. for patients with positive sentinel nodes, lymph node dissection was performed. results: at least one sentinel node could be harvested in all patients. the mean number of sentinel nodes was 1.66. detection rate with radiotracer and blue dye was 100% and 75% respectively. 30% of the patients had positive sentinel nodes. one patient in the pediatric age range and one head and neck melanoma were included in our study with successful sentinel node mapping. conclusion: sentinel lymph node biopsy using tc-99m antimony sulfide colloid is a reliable and safe method in melanoma patients which can help in treatment planning and patient's ultimate prognosis.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Sentinel lymph node biopsy in melanoma patients: An experience with Tc-99m antimony sulfide colloid

  Introduction: Sentinel lymph node biopsy is the standard procedure for lymph node staging in intermediate thickness melanoma. In Iran, this procedure has not been addressed sufficiently. In this study, we report our experience in this area. Methods: Ten consecutive patients with intermediate thickness melanoma where included in our study. 1.5 mCi of Tc-99m antimony...

full text

Sentinel node detection failure due to defective labeling and large particle size of Tc-99m antimony sulfide colloid

  Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel n...

full text

The efficacy of Tc-99m sestamibi for sentinel node mapping in breast carcinomas: comparison with Tc-99m antimony sulphide colloid.

BACKGROUND To study the value of periareolar intra-dermal injection of Tc-99m sestamibi (MIBI) for sentinel node mapping in breast carcinoma. MATERIAL AND METHODS Fifty patients with early-stage breast cancer were included in our study. 17.5 MBq Tc-99m-MIBI was injected intradermally to 25 patients and the remainders were injected with the same dose of Tc-99m-antimony sulphide colloid. Anteri...

full text

Sentinel lymph node biopsy correctly predicts regional lymph node recurrence in trunk malignant melanoma with multiple drainage basins

We report a young male with an initial excisional biopsy report of melanoma of the lower back, referred to our hospital for complete excision and sentinel lymph node (SLN) biopsy.  Four peritumoral intradermal Tc-99m phytate injection was performed and SLNs were detected in both axillary and right inguinal regions. On the biopsy only the right axillary SLN was metastatic leading to right axilla...

full text

sentinel node detection failure due to defective labeling and large particle size of tc-99m antimony sulfide colloid

introduction: many radiotracers have been used for sentinel node mapping with acceptable results. the main difference between these radiotracers is the particle size. in the current study, we reported defective labeling of tc-99m antimony sulfide colloid which resulted in large particle size. methods: tc-99m-antimony sulfide colloid was used for axillary sentinel node mapping of 45 breast cance...

full text

Sentinel lymph node biopsy in patients with thin melanoma.

OBJECTIVE To define the percentage of positive sentinel lymph node biopsies and identify risk factors for the presence of lymph node disease in patients with melanomas less than or equal to 1 mm in depth. DESIGN Retrospective chart review. SETTING Washington University School of Medicine and Barnes-Jewish Hospital, St Louis, Mo, a melanoma referral center with outpatient surgical care. PA...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of nuclear medicine

Publisher: tehran university of medical sciences

ISSN 1681-2824

volume 18

issue 1 2010

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023