performance comparison of four commercial ge discovery pet/ct scanners: a monte carlo study using gate

Authors

parham geramifar

mohammad reza ay

mojtaba shamsaie zafarghandi

george loudos

arman rahmim

abstract

combined pet/ct scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. as the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner performances on an objective basis. in this study we evaluate and compare the performance of 4 commercial ge pet/ct cameras, the (i) bgo-based discovery ls pet/ct (dls), (ii) the bgo-based discovery st pet/ct (dst), (iii) the bgo-based discovery ste pet/ct (dste) and finally (iv) the lyso-based discovery rx pet/ct (drx) scanner using the geant4 application for tomographic emission (gate). gate is an open source monte carlo simulation platform developed for pet and spect studies and is supported by the opengate collaboration. in accordance with the national electrical manufactures association (nema) nu 2-2001 protocols, the validation of models is carried out against actual published measurements and the performance comparison is done for sensitivity, scatter fraction and count rate performance, showing very similar performance compared with published results, thus enabling investigations to better model system performance (e.g. resolution degradation) within the reconstruction task.. the simulated results demonstrate highest sensitivity performance with the dst (though with the highest scatter fraction), and highest necr performance for the lyso-based drx, the results also show that drx, dls and dste pet/ct cameras have nearly the same amount of scatter fraction.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

full text

Performance Comparison of Four Commercial GE Discovery PET/CT Scanners: A Monte Carlo Study Using GATE

Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner performances on an objective ...

full text

Rabbit internal dosimetry for iodine-131 using GATE Monte Carlo simulation code: a preclinical trial

Introduction: One of the main concerns in administration of radiotracers, especially in therapeutic arm, is the amount of delivered dose to the different organs. Individual variations of anatomy, physiology and underlying pathology in the patients lead to alteration of administered activity. In the current study we preclinically applied internal dosimetry using an animal mod...

full text

a comparison between gate and mcnpx monte carlo codes in simulation of medical linear accelerator

radiotherapy dose calculations can be evaluated by monte carlo (mc) simulations with acceptable accuracy for dose prediction in complicated treatment plans. in this work, standard, livermore and penelope electromagnetic (em) physics packages of geant4 application for tomographic emission (gate) 6.1 were compared versus monte carlo n-particle extended (mcnpx) 2.6 in simulation of 6 mv photon lin...

full text

Monte-Carlo Expression Discovery

Monte-Carlo Tree Search is a general search algorithm that gives good results in games. Genetic Programming evaluates and combines trees to discover expressions that maximize a given fitness function. In this paper Monte-Carlo Tree Search is used to generate expressions that are evaluated in the same way as in Genetic Programming. Monte-Carlo Tree Search is transformed in order to search expres...

full text

Dynamic Monte Carlo study of isolated-gate InAs/AlSb HEMTs

In this work, by means of Monte Carlo simulations, the static and dynamic behavior of isolated-gate InAs/AlSb high electron mobility transistors (Sb-HEMTs) has been studied and compared with experimental results. The influence of the existence of a native oxide under the gate, the value of the surface charges in the gate recess and the possible variation of electron sheet carrier density, ns, h...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of nuclear medicine

Publisher: tehran university of medical sciences

ISSN 1681-2824

volume 17

issue 2 2009

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023