diffuse bilateral breast uptake on the myocardial perfusion spect of a nursing female

Authors

ramin sadeghi

seyed rasoul zakavi

mehdi momennezhad

vahid reza dabbagh kakhki

abstract

bilateral diffuse intense breast uptake was noted in a 40 year old female who was evaluated with tc-99m sestamibi (mibi) myocardial perfusion scan for possible ischemia. she was breast feeding her 1.5 year old child. the intense uptake in the breasts was superimposed on the apical and anteroapical regions of the myocardium and caused interpretation problem. we recommend considering tc-99m mibi breast uptake during breast feeding as a possible cause of non-interpretable, superimposition of radiotracer on the myocardium in myocardial perfusion scan.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Diffuse bilateral breast uptake on the myocardial perfusion SPECT of a nursing female

  Bilateral diffuse intense breast uptake was noted in a 40 year old female who was evaluated with Tc-99m sestamibi (MIBI) myocardial perfusion scan for possible ischemia. She was breast feeding her 1.5 year old child. The intense uptake in the breasts was superimposed on the apical and anteroapical regions of the myocardium and caused interpretation problem. We recom...

full text

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

full text

Evaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy

Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...

full text

Covid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT

A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...

full text

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically. Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be ...

full text

myocardial perfusion spect: perfusion quantification

different software tools for quantification of myocardial perfusion spect (mps) studies are routinely used. several perfusion parameters can be computed automatically.  interpretation of the mps should start with visual inspection of the rotating planar images, visual analysis of reconstructed spect slices and then quantitative analysis to confirm the visual impression. quantification should be...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of nuclear medicine

Publisher: tehran university of medical sciences

ISSN 1681-2824

volume 16

issue 2 2008

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023