ti-6al-4v synthesized by mechanical alloy method and mechanical and bioactivity properties of ti-6al-4v/ha-clay nano composite

Authors

mohammad ali motallebi

master of science, mechanical engineering, islamic azad university of khomeini shahr ebrahim karamian

assistant professor, faculty of mechanics, institute of materials, school of materials, islamic azad university, najaf abad magid karimian

assistant professor, faculty of mechanics, university of khomeini shahr

abstract

nowadays, titanium-based alloys are among the most attractive metallic materials for biomedical applications (as implants) due to their non-biodegradability, low density, good mechanical properties as well as their good biocompatibility. hydroxyapatite (ca10 (po4)6(oh)2, ha) has been widely used for biomedical applications due to its bioactive, biocompatible and osteoconductive properties. firstly, ti-6al-4v alloy was synthesized by mechanical alloy method with high energy ball milling plantery, hebm. and then in this work began with preparing hydroxyapatite, ha, from bovine bones and continued with composite in nano clay powder .at the end a hydroxyapatite–clay (ha/clay) nanocomposite ceramic, 80 wt.% of ha and 20 wt.% nano clay powder, was synthesized through a mechanical method , hebm. the ability of apatite formation on the produced nanocomposite samples, as a yardstick for evaluation of the bioactivity, was estimated by using simulated body fluid. according to the results obtained mechanical and density values and bioactivity behavior, the sample containing 20 wt. % ha/clay indicated the optimal properties in mechanical and bioactivity behavior. in fact, this nano composite sample, ti-6al-4v/20 ha-clay, is good candidate for medical purposes, bone tissue applications.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Ti-6Al-4V Synthesized by Mechanical Alloy Method and Mechanical and Bioactivity Properties of Ti-6Al-4V/HA-Clay Nano composite

Nowadays, titanium-based alloys are among the most attractive metallic materials for biomedical applications (as implants) due to their non-biodegradability, low density, good mechanical properties as well as their good biocompatibility. Hydroxyapatite (Ca10 (PO4)6(OH)2, HA) has been widely used for biomedical applications due to its bioactive, biocompatible and osteoconductive properties. Firs...

full text

Fatigue of Ti-6Al-4V

Metallic biomaterials have essentially three fields of use; these are the artificial hip joints, screw, plates and nails for internal fixation of fractures, and dental implants. Any of these devices must support high mechanical load and resistance of material against breakage is essential. High mechanical properties are needed for structural efficiency of surgical and dental implants. But their...

full text

Precision Grinding of Titanium (Ti-6Al-4V) Alloy Using Nanolubrication

In this current era of competitive machinery productions, the industries are designed to place more emphasis on the product quality and reduction of cost whilst abiding by the pollution-preventing policy. In attempting to delve into the concerns, the industries are aware that the effectiveness of existing lubrication systems must be improved to achieve power-efficient and pollutionpreventing ma...

full text

Microstructure and Mechanical Properties of Direct Metal Laser Sintered Ti- 6al-4v

Direct metal laser sintering (DMLS) is a selective laser melting (SLM) manufacturing process that can produce near net shape parts from metallic powders. A range of materials are suitable for SLM; they include various metals such as titanium, steel, aluminium, and cobalt-chrome alloys. This paper forms part of a research drive that aims to evaluate the material performance of the SLM-manufactur...

full text

Laser Powder Cladding of Ti-6Al-4V α/β Alloy

Laser cladding process was performed on a commercial Ti-6Al-4V (α + β) titanium alloy by means of tungsten carbide-nickel based alloy powder blend. Nd:YAG laser with a 2.2-KW continuous wave was used with coaxial jet nozzle coupled with a standard powder feeding system. Four-track deposition of a blended powder consisting of 60 wt % tungsten carbide (WC) and 40 wt % NiCrBSi was successfully mad...

full text

Osteoblastic behavior to zirconium coating on Ti-6Al-4V alloy

PURPOSE The purpose of this study was to assess the surface characteristics and the biocompatibility of zirconium (Zr) coating on Ti-6Al-4V alloy surface by radio frequency (RF) magnetron sputtering method. MATERIALS AND METHODS The zirconium films were developed on Ti-6Al-4V discs using RF magnetron sputtering method. Surface profile, surface composition, surface roughness and surface energy...

full text

My Resources

Save resource for easier access later


Journal title:
فصلنامه علمی پژوهشی مهندسی مکانیک جامدات واحد خمینی شهر

جلد ۹، شماره ۳، صفحات ۴۷۹-۴۹۰

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023