radiographic vertical bone loss evaluation around dental implants following one year of functional loading

Authors

aar. rasouli ghahroudi assistant professor, department of periodontology, school of dentistry, tehran university of medical

ar talaeepour professor, department of oral and maxillofacial radiology, school of dentistry, tehran university of

a. mesgarzadeh associate professor, department of oral and maxillofacial surgery, school of dentistry, tehran unive

ar. rokn associate professor, department of periodontology, school of dentistry, tehran university of medical

abstract

objective: vertical bone loss evaluations in the nobel biocare replace® select tapered tm implant system in the human after one-year loading time. materials and methods: this retrospective cross-sectional study was performed on 31 patients (14 men, 17 women; mean age, 60.39 years) receiving 170 implants (mean, 5.48 for each patient) of groovy and non-groovy designs in the nobel biocare replace® select tapered tm system. the marginal bone loss was measured at mesial and distal aspects of the implants on opg x-rays after one-year follow-up. the data regarding the patient's gender, age, history of disease, smoking, bone type at implant location, loading time of prosthesis and implant, implant design, diameter and length were recorded by the patients' records and interview. the data were subjected to multiple linear regression and pearson coefficient ratio regarding different factors. results: the mean (standard deviation) distal, mesial and overall bone loss was 0.688 mm (0.851), 0.665 mm (0.849) and 0.935 mm (0.905), respectively in the studied implants. no significant differences were found regarding implant location, bone quality at the implant region, implant design and bone graft reception. in addition, no significant correlation was found between the occurred bone loss and implant diameter, length and number of used splints. conclusion: due to the criteria mentioned for implant success in term of bone loss values after one-year loading time, noble biocare replace® select tapered tm implant system is an acceptable treatment option for implant restorations in this regard.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Radiographic Vertical Bone Loss Evaluation around Dental Implants Following One Year of Functional Loading

OBJECTIVE Vertical bone loss evaluations in the Nobel Biocare Replace(®) Select Tapered (™) implant system in the human after one-year loading time. MATERIALS AND METHODS This retrospective cross-sectional study was performed on 31 patients (14 men, 17 women; mean age, 60.39 years) receiving 170 implants (mean, 5.48 for each patient) of Groovy and Non-groovy designs in the Nobel Biocare Repla...

full text

Radiographic Evaluation of Crestal Bone Loss Around Dental Implants in Maxilla and Mandible: One Year Prospective Clinical Study.

PURPOSE The aim of the study was to analyze the amount of maxillary and mandibular crestal bone loss around Bredent Sky Blue type of implants of different dimensions one year after implantation. MATERIALS AND METHODS 36 implants of diameter 3.5 x 10 mm were inserted in the maxilla and 12 in the mandible. 52 implants of diameter 4.0 x 8 mm were inserted in the maxilla, and 61 in the mandible (...

full text

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

full text

Changes in crestal bone around endosseous implants during functional loading: a radiographic evaluation in edentulous patients comparing different implant designs.

Marginal bone changes around titanium plasma-sprayed implants (n = 240) placed in the mandibular interforaminal regions of 120 edentulous patients were assessed over 5 years of follow-up, with emphasis on the influence of the locations of the microgap and rough/smooth border. Marginal bone changes were measured on standardized radiographs. Locations of the microgap and the rough/smooth border w...

full text

My Resources

Save resource for easier access later


Journal title:
journal of dentistry, tehran university of medical sciences

جلد ۷، شماره ۲، صفحات ۸۹-۹۷

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023