comparison of three attachments in implant-tissue supported overdentures: an in vitro study

Authors

f. tabatabaian assistant professor, department of prosthodontics, school of dentistry, shahid beheshti university o

f. alaie associate professor, department of prosthodontics, school of dentistry, shahid beheshti university

k. seyedan uassistant professor, department of prosthodontics, school of dentistry, shahid beheshti niversity o

abstract

objective: retention and resistance of the implant-tissue supported overdenture may be affected by the type of attachment. the aim of this research was to compare the retention and resistance of nobel biocare ball (nbb), nobel biocare bar and clip (nbbc) and sterngold era red (erar) attachments on an implant-tissue supported overdenture model. materials and methods: the attachment samples were divided into 3 groups of nbb, nbbc, and erar (5 samples in each group). two parallel nobel biocare branemark implants were placed symmetrically at the symphysis region of a mandibular test model. a metallic overdenture was fabricated precisely adapted to the model and attached to a zwick testing machine (crosshead speed of 51 mm/min). dislodging tensile forces were applied in three vertical, oblique, anterior-posterior directions and two situations, at the beginning and after 100 times of insertion/removal of the overdenture, for each sample. the maximum dislodging force was measured. a one-way anova test was employed followed by tukey's test. results: erar was the most retentive and resistant in both situations. nbb and nbbc showed the same anterior-posterior resistance at the beginning. all test groups represented a large amount of retention and resistance loss after the insertion/removal of the overdenture, while nbbc showed a higher loss of anterior-posterior resistance than nb. conclusion: a highest level of retention and resistance was seen in erar. the retention and resistance were affected by the wear of attachments.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Comparison of Three Attachments in Implant-Tissue Supported Overdentures: An In Vitro Study

OBJECTIVE Retention and resistance of the implant-tissue supported overdenture may be affected by the type of attachment. The aim of this research was to compare the retention and resistance of Nobel Biocare Ball (NBB), Nobel Biocare Bar and Clip (NBBC) and Sterngold ERA Red (ERAR) attachments on an implant-tissue supported overdenture model. MATERIALS AND METHODS The attachment samples were ...

full text

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...

full text

Comparison of changes in retentive force of three stud attachments for implant overdentures

PURPOSE The aim of this study was to compare the changes in retentive force of stud attachments for implant overdentures by in vitro 2-year-wear simulation. MATERIALS AND METHODS Three commercially available attachment systems were investigated: Kerator blue, O-ring red, and EZ lock. Two implant fixtures were embedded in parallel in each custom base mounting. Five pairs of each attachment sys...

full text

Performance of attachments used in implant-supported overdentures: review of trends in the literature

The purpose of this review is to examine the performance of attachments used in implant-supported overdenture (IOD) in both clinical and in vitro settings and report the compiled findings, comparisons, and trends in the research literature. Articles published in PubMed on IOD attachment systems and performance were reviewed. Non-original articles were excluded. For each article included, the ty...

full text

Implant-supported overdentures: a longitudinal prospective study.

The aim of this study was to evaluate the clinical function and long-term prognosis of overdentures retained by a small number of implants in the maxilla and mandible using one of two different attachment systems. Included in the study were all patients referred to specialty clinics in Jönköping and Linköping, Sweden, during the treatment period who needed an overdenture and could be provided w...

full text

My Resources

Save resource for easier access later


Journal title:
journal of dentistry, tehran university of medical sciences

جلد ۷، شماره ۳، صفحات ۱۱۳-۱۱۸

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023