effect of the number of implants on stress distribution of anterior implant-supported fixed prostheses combined with a removable partial denture: a finite element analysis.

Authors

minoo mahshid associate professor, prosthodontics department, dental school, shahid beheshti university of medical sciences, tehran, iran.

allahyar geramy professor, dental research center dentistry research institute & department of orthodontics, tehran university of medical sciences, tehran, iran.

massoud ejlali assistant professor, prosthodontics department, dental school, shahid beheshti university of medical sciences, tehran, iran.

majid sedaghat monfared assistant professor, prosthodontics department, dental school, shahid beheshti university of medical sciences, tehran, iran.

abstract

the main goal of this study was to evaluate differences in stress distribution relevant to the number of implants under an anterior bridge when combined with a removable partial denture in the posterior region.four three-dimensional finite element models (3d fem) were designed from a mandible containing an implant-supported bridge extending between canines, and a bilateral distal extension removable partial denture. a nonrigid connection was selected as the attachment method between the partial denture and the anterior implant-supported fixed prosthesis; 2, 3, 4 and 5 implants supporting the bridge all with 10mm length and 3.8 mm diameter were assessed. with the aid of the finite element program ansys 8.0, the models were loaded and von mises stresses were evaluated.in spongy bone, stress forces showed a decrease from 2 implants to 4 implants but showed an increase in the 5-implant model. stresses on cortical bone of terminal implants were in similar range in the 2-, 3- and 4-implant models. while, in the 5-implant model the amount of stresses on terminal implants increased dramatically. the stresses on implants were nearly similar in all models, with the greatest amount on terminal implants.within the limitations of this study, 2-, 3- and 4-implant models showed less stress on cortical and spongy bone in comparison with the 5-implant model. the stresses transferred to implants were nearly similar.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Effect of the Number of Implants on Stress Distribution of Anterior Implant-Supported Fixed Prostheses Combined with a Removable Partial Denture: A Finite Element Analysis

OBJECTIVE The main goal of this study was to evaluate differences in stress distribution relevant to the number of implants under an anterior bridge when combined with a removable partial denture in the posterior region. MATERIALS AND METHODS Four three-dimensional finite element models (3D FEM) were designed from a mandible containing an implant-supported bridge extending between canines, an...

full text

Stress Distribution in Natural Tooth and Implant Supported Removable Partial Denture with Different Attachment Types: A Photoelastic Analysis

Background and Aim: Different attachment designs have been developed to connect implant to natural teeth in partial dentures; however, adequate studies have not been performed to determine stress distribution patterns in these designs. The present study aimed to assess stress distribution patterns in natural tooth and implant supported removable partial denture with different attachment designs...

full text

Periodontal ligament influence on the stress distribution in a removable partial denture supported by implant: a finite element analysis

OBJECTIVES The non-homogenous aspect of periodontal ligament (PDL) has been examined using finite element analysis (FEA) to better simulate PDL behavior. The aim of this study was to assess, by 2-D FEA, the influence of non-homogenous PDL on the stress distribution when the free-end saddle removable partial denture (RPD) is partially supported by an osseointegrated implant. MATERIAL AND METHO...

full text

the effectiveness of adding a supporting implant in stress distribution of long span fixed partial denture (3d finite element analysis)

background and aim of study: long span is seen in many clinical situations, treatment planning options of these cases are difficult and may require: fpd, rpd or isp. each option has its own disadvantages: mechanical, patient relief and cost respectively. this article will evaluate the stress distribution of another treatment option which is adding a single supporting implant to the fpd by using...

full text

the effect of consciousness raising (c-r) on the reduction of translational errors: a case study

در دوره های آموزش ترجمه استادان بیشتر سعی دارند دانشجویان را با انواع متون آشنا سازند، درحالی که کمتر به خطاهای مکرر آنان در متن ترجمه شده می پردازند. اهمیت تحقیق حاضر مبنی بر ارتکاب مکرر خطاهای ترجمانی حتی بعد از گذراندن دوره های تخصصی ترجمه از سوی دانشجویان است. هدف از آن تاکید بر خطاهای رایج میان دانشجویان مترجمی و کاهش این خطاها با افزایش آگاهی و هوشیاری دانشجویان از بروز آنها است.از آنجا ک...