comparison of implant stability using resonance frequency analysis: osteotome versus conventional drilling

Authors

rokhsareh sadeghi

amir reza rokn

asghar miremadi

abstract

objectives: implant primary stability is one of the important factors in achieving implant success. the osteotome technique may improve primary stability in patients with poor bone quality. the aim of this study was to compare implant stability using two different techniques namely osteotome versus conventional drilling in the posterior maxilla. materials and methods: in this controlled randomized clinical trial, 54 dental implants were placed in 32 patients; 29 implants were placed in the osteotome group and 25   in the conventional drilling group. implant stability was assessed at four time intervals namely at baseline, one, two and three months after implant placement using resonance frequency analysis (rfa). results: primary stability based on implant stability quotient (isq) units was 71.4±7 for the osteotome group and 67.4±10 for the control group. there was no statistically significant difference between the two groups in implant stability at any of the measurement times. in each group, changes in implant stability from baseline to one month and also from two months to three months post-operatively were not significant but from one month to two months after implant placement, implant stability showed a significant increase in both groups.   conclusion : the results of this study revealed that in both techniques, good implant stability was achieved and osteotome technique did not have any advantage compared to conventional drilling in this regard.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Comparison of Implant Stability Using Resonance Frequency Analysis: Osteotome Versus Conventional Drilling

OBJECTIVES Implant primary stability is one of the important factors in achieving implant success. The osteotome technique may improve primary stability in patients with poor bone quality. The aim of this study was to compare implant stability using two different techniques namely osteotome versus conventional drilling in the posterior maxilla. MATERIALS AND METHODS In this controlled randomi...

full text

Resonance frequency analysis of implant stability in augmented and non-augmented sinus sites

Background and aim:  Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...

full text

Comparison of Implant Stability in Sinus Lift Surgery Using Autogenous Versus Allogeneic Bone Grafts

Background and aim: The most common method of increasing implant stability in the posterior maxilla comprises the reinforcement of bone height using bone grafts in sinus lift surgery. The purpose of the present study was to compare autogenous and allogeneic bone grafts in implant stability after open sinus lift surgery. Materials and methods: This split-mouth clinical trial compared the implant...

full text

Comparison of peri-implant bone loss between conventional drilling with irrigation versus low-speed drilling without irrigation

BACKGROUND To compare the technique of high speed drilling with irrigation and low speed drilling without irrigation in order to evaluate the success rate and peri-implant bone loss at 12 months of follow-up. MATERIAL AND METHODS A randomized, controlled, parallel-group clinical trial was carried out in patients requiring dental implants to rehabilitate their unitary edentulism. Patients were...

full text

RESONANCE FREQUENCY ANALYSIS FOR IMPLANT STABILITY MEASUREMENTS. A review

The resonance frequency analysis (RFA) technique for implant stability measurements was developed by Meredith and coworkers more than 20 years ago. RFA makes use of a transducer (peg), which is attached to the implant and excited over a range of frequencies by electro-magnetic waves to measure the resonance frequency (RF) of the transducer. The underlying RF measurements in Hz are translated to...

full text

Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis

BACKGROUND This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). MATERIAL AND METHODS Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remain...

full text

My Resources

Save resource for easier access later


Journal title:
journal of dentistry, tehran university of medical sciences

جلد ۱۲، شماره ۹، صفحات ۶۴۷-۶۵۴

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023