a comparison of radiographic film densitometry using a new computerized tool with a digital densitometer
Authors
abstract
objectives: the purpose of this study was to develop and test a new tool for radiographic densitometry by combining periapical films and aluminum step wedge. materials and methods: we reviewed 50 kodak e-speed intraoral films. an aluminum step wedge consisting of 16 steps was constructed. each step was 1mmx3mx10mm. the step wedge was exposed to varying exposure times, ranging from 0.05 second to 0.5 second, increasing in 0.05 second increments. films were digitalized after processing and the matlab software algorithm was ran subsequently. density of the films was measured again using a digital densitometer. in order to compare the two imaging techniques, three steps were selected. output data from the matlab algorithm were compared with data obtained from the digital densitometer. results: the new method could detect significant differences between subsequent exposure times in step 7, while the densitometer did that in steps 7 and 12. the new method’s sensitivity in determining density changes was 5.26%, 84.1% and 93.02% in steps 2, 7, and 12 respectively. conclusions: our new method has an acceptable sensitivity for determining density changes of at least 7 mmeq/al.
similar resources
A Comparison of Radiographic Film Densitometry Using a New Computerized Tool with a Digital Densitometer
OBJECTIVES The purpose of this study was to develop and test a new tool for radiographic densitometry by combining periapical films and aluminum step wedge. MATERIALS AND METHODS We reviewed 50 Kodak E-speed intraoral films. An aluminum step wedge consisting of 16 steps was constructed. Each step was 1mm×3m×10mm. The step wedge was exposed to varying exposure times, ranging from 0.05 second t...
full textA study of densitometry comparison among three radiographic processing solutions
ABSTRACT Background: The radiographic image accuracy depends on the X-ray film information visibility. Good visibility is found by good contrast. Radiation exposure parameters (kVp, mAs) and film processing conditions have impact on contrast. In dentistry radiography machines, exposure time and processing procedure are set by radiographer. No optimized exposure time and process...
full texta comparison of linguistic and pragmatic knowledge: a case of iranian learners of english
در این تحقیق دانش زبانشناسی و کاربردشناسی زبان آموزان ایرانی در سطح بالای متوسط مقایسه شد. 50 دانش آموز با سابقه آموزشی مشابه از شش آموزشگاه زبان مختلف در دو آزمون دانش زبانشناسی و آزمون دانش گفتار شناسی زبان انگلیسی شرکت کردند که سوالات هر دو تست توسط محقق تهیه شده بود. همچنین در این تحقیق کارایی کتابهای آموزشی زبان در فراهم آوردن درون داد کافی برای زبان آموزان ایرانی به عنوان هدف جانبی تحقیق ...
15 صفحه اولa comparison of teachers and supervisors, with respect to teacher efficacy and reflection
supervisors play an undeniable role in training teachers, before starting their professional experience by preparing them, at the initial years of their teaching by checking their work within the proper framework, and later on during their teaching by assessing their progress. but surprisingly, exploring their attributes, professional demands, and qualifications has remained a neglected theme i...
15 صفحه اولconstruction and validation of a computerized adaptive translation test (a receptive based study)
آزمون انطباقی رایانه ای (cat) روشی نوین برای سنجش سطح علمی دانش آموزان می باشد. در حقیقت آزمون های رایانه ای با سرعت بالایی به سمت و سوی جایگزین عملی برای آزمون های کاغذی می روند (کینگزبری، هاوسر، 1993). مقاله حاضر به دنبال آزمون انطباقی رایانه ای برای ترجمه می باشد. بدین منظور دو پرسشنامه مشتمل بر 55 تست ترجمه میان 102 آزمودنی و 10 مدرس زبان انگلیسی پخش گردید. پرسشنامه اول میان 102 دانشجوی س...
Interobserver Variability of Radiographic Assessment using a Mobile Messaging Application as a Teleconsultation Tool
Background: To examine whether interobserver reliability, decision-making, and confidence in decision-making in thetreatment of distal radius fractures changes if radiographs are viewed on a messenger application on a mobile phonecompared to a standard DICOM viewer.Methods: Radiographs of distal radius fractures were presented to surgeons on either a smart phone using a mobilemessenger applicat...
full textMy Resources
Save resource for easier access later
Journal title:
journal of dentistry, tehran university of medical sciencesجلد ۱۳، شماره ۴، صفحات ۲۵۲-۲۶۰
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023