loss of excitation detection in doubly fed induction generator by voltage and reactive power rate
Authors
abstract
the doubly fed induction generator (dfig) is one of the most popular technologies used in wind power systems. with the growing use of dfigs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. loss of excitation (loe) event is among the most frequent failures in electric generators. however, loe detection studies heretofore were usually confined to synchronous generators. common loe detection methods are based on impedance trajectory which makes the system slow and also prone to interpret a stable power swing (sps) as a loe fault. this paper suggests a new method to detect the loe based on the measured variables from the dfig terminal. in this combined method for loe detection, the rate of change of both the terminal voltage and the output reactive power are utilized and for sps detection, the fast fourier transform (fft) analysis of the output instantaneous active power has been used. the performance of the proposed method was evaluated using matlab/simulink interface for various power capacities and operating conditions. the results proved the method's quickness, simplicity and security.
similar resources
Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate
The doubly fed induction generator (DFIG) is one of the most popular technologies used in wind power systems. With the growing use of DFIGs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. Loss of excitation (LOE) event is among the most frequent failures in electric generators. However, LOE detection stud...
full textSliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition
This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...
full textLow Voltage Ride-Through Capability Improvement of Doubly Fed Induction Generator using DVR and SMES
Abstract: With the growth of communities and the increasing need for electricity, and because of the many benefits of renewable energy sources, the wind turbine has become a completely commercial and inevitable process, with increasing penetration into the electricity grid. Distribution networks, on the other hand, are subject to fault that cause power fluctuations and outflow of wind units. In...
full textOptimal Operation of Doubly-fed Induction Generator used in a Grid-Connected Wind Power System
In this paper, a wind power system based on a doubly-fed induction generator (DFIG) is modeled and simulated. To guarantee high-performance control of the powers injected into the grid by the wind turbine, five intelligent super-twisting sliding mode controllers (STSMC) are used to eliminate the active power and current ripples of the DFIG. The STSMC controller is a high-order sliding mode cont...
full textVSC-based direct torque and reactive power control of doubly fed induction generator
This paper proposes a novel direct torque and reactive power control (DTC) for grid-connected doubly fed induction generators (DFIGs) in the wind power generation applications. The proposed DTC strategy employs a variable structure control (VSC) scheme to calculate the required rotor control voltage directly and to eliminate the instantaneous errors of active and reactive powers without involvi...
full textLyapunov-Based Robust Power Controllers for a Doubly Fed Induction Generator
In this work, a robust nonlinear control technique of a doubly fed induction generator (DFIG) intended for wind energy systems has been proposed. The principal idea in this article is to decouple the active and reactive power of the DFIG with high robustness using the backstepping strategy. The principle of this control method is based on the Lyapunov function, in order to guarantee the global ...
full textMy Resources
Save resource for easier access later
Journal title:
iranian journal of electrical and electronic engineeringجلد ۱۲، شماره ۴، صفحات ۲۷۰-۲۸۰
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023