magnetic resonance imaging of feline eye

Authors

d. vosough

b. shojaei

m. molazem

abstract

the purpose of this study was to investigate magnetic resonance imaging (mri) of the normal feline eyeand optic nerves using t1-weighted and t2-weighted images. a total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. magnetic resonance imaging data werecollected using gemsow (philips) at a magnetic field strength of 1.5 t. dorsal, sagittal, and transverseplane images were obtained from left and right eyes. intraocular structures of the cats visible on t1-weighted and t2-weighted images include cornea, anterior chamber, posterior chamber, lens, iris, sclera, and chiasma. cornea was well detected in t1-weighted, the iris in t2-weighted and chiasma was well detected in t2- weighted in dorsal plane. measurements of the visible structures on t1-weighted and t2-weighted images did not show any significant difference between the left and right eyes (p>0.05). mri provides excellent anatomical detail of the feline eye and optic nerve due to its superior soft tissue contrast and its multiplanar and multislice imaging capability.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Magnetic resonance imaging of feline eye

The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...

full text

Fetal Eye Movements on Magnetic Resonance Imaging

OBJECTIVES Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. METHODS Dynamic SSFP sequences were acquired in ...

full text

Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging

Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...

full text

Segmentation of Magnetic Resonance Brain Imaging Based on Graph Theory

Introduction: Segmentation of brain images especially from magnetic resonance imaging (MRI) is an essential requirement in medical imaging since the tissues, edges, and boundaries between them are ambiguous and difficult to detect, due to the proximity of the brightness levels of the images. Material and Methods: In this paper, the graph-base...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of veterinary research

Publisher: shiraz university

ISSN 1728-1997

volume 10

issue 1 2009

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023