assessment of color changes in vita 3d-master shade guide after sterilization and disinfection
Authors
abstract
purpose:dental shade guides are commonly used for color determination and should be disinfected and sterilized. the purpose of this study was to evaluate the color change of vita 3d master shade tabs after disinfection and sterilization. material and methods:overall, 98 samples (shade tabs) were randomly selected from 14 new, unused vita 3d sets, including the following shades: 2m1, 3l1.5, 3m1, 3m2, 3m3, 3r1.5 and 4m1. in each set, values of 2, 3 and 4, chroma of 1, 2 and 3 and hue were selected for the comparison of different shades. all tabs were measured using the vita easyshade device at baseline. the first group was disinfected with deconex and the second group was sterilized by autoclaving in a simulated annual application. all the tabs were measured again using the same device. this process was repeated to simulate 2 and 3 years of usage. statistical analysis was conducted by repeated measures analysis of variance (anova) and independent t-test and paired sample t-test. results:in the disinfected group, we observed significant differences in value and chroma in all periods (p˂0.001). however, hue showed no significant difference after the first year of simulated treatment (p=0.527), though it was significantly different in the second and third simulations (p˂0.001). in the sterilized group, all variables showed a significant difference for each year (p˂0.05). considering total color difference (δe), there was a significant difference between the two groups in the first, second and third simulated years; δe increased in the sterilized group more than in the disinfected samples (p˂0.001). conclusions: the color change of shade tabs was significant both after disinfection by a chemical solution and by sterilization through autoclaving. however, although disinfectants may not have a clinically important effect, sterilization should be considered as an interfering factor during color-matching procedure.
similar resources
Assessment of Color Changes in Vita 3D-Master Shade Guide after Sterilization and Disinfection
Purpose:Dental shade guides are commonly used for color determination and should be disinfected and sterilized. The purpose of this study was to evaluate the color change of Vita 3D Master shade tabs after disinfection and sterilization. Material and methods:Overall, 98 samples (shade tabs) were randomly selected from 14 new, unused Vita 3D sets, including the following shades: 2M1, 3L1.5, 3M1,...
full textAssessment of Color Changes in Vita 3D-Master Shade Guide after Sterilization and Disinfection
Purpose: Dental shade guides are commonly used for color determination and should be disinfected and sterilized. The purpose of this study was to evaluate the color change of Vita 3D Master shade tabs after disinfection and sterilization. Material and methods: Overall, 98 samples (shade tabs) were randomly selected from 14 new, unused Vita 3D sets, including the following shades: 2M1, 3L1.5, 3M...
full textDiscoloration of Vita Classical Shade Guide by Glutaraldehyde Disinfectant
Background and Aim: Shade guide discoloration after disinfection can interfere with the appropriate color selection for dental restorations. Since one of the most important issues for patients is the color of the final restoration, the discoloration of shade guides due to disinfectants will be important. Infection control is a definite and important matter in dentistry. Due to the contradictory...
full textبررسی فراوانی رنگ دندان سانترال ماگزیلا با دو نوع نمونه رنگ در مراجعهکنندگان به بخش پروتزهای دندانی دانشکده دندانپزشکی بابل
Introduction: Knowing the color distribution of natural teeth and as a result the availability of the dentures teeth with the required colors is essential for patients. Therefore, the aim of this study was to compare the color of natural teeth by two shade guides, Vita tooth guide 3D-Master and Vitapan Classical, in patients referring to prosthodontics department of Babol dental school in 2013...
full textColor Parameters of the Chromascop Shade Guide
The purposes of this study are: (1) determine the color of the twenty shades in the Ivoclar’s Chromascop shade guide, (2) determine the color representation of the shade guide described as coverage error (CE), and (3) compare this shade guide with the Vita Classical and Bioform shade guides. The spectral data was collected using Beckman model DU reflectance spectrophotometer equipped with an in...
full textReliability of conventional shade guides in teeth color determination.
BACKGROUND/AIM Color matching in prosthodontic therapy is a very important task because it influences the esthetic value of dental restorations. Visual shade matching represents the most frequently applied method in clinical practice. Instrumental measurements provide objective and quantified data in color assessment of natural teeth and restorations. In instrumental shade analysis, the goal is...
full textMy Resources
Save resource for easier access later
Journal title:
journal of dental materials and techniquesجلد ۶، شماره ۲، صفحات ۴۸-۵۳
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023