monte carlo simulation of electron beams produced by liac intraoperative radiation therapy accelerator
Authors
abstract
background: one of the main problems of dedicated iort accelerators is to determine dosimetric characteristics of the electron beams. monte carlo simulation of iort accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry. materials and methods: liac accelerator head was modeled using the beamnrcmonte carlo simulation system. phase-space files were generated at the bottom of the applicators. these phase-space files were used as an input source in dosxyznrc and beamdp codes for dose calculation and analysis of the characteristic of the electron beams in all applicators and energies. results: the results of monte carlo calculations are in very close agreement with the measurements. there is a decrease in the peak of the initial spectrum when electrons come from the end of accelerator wave guide to the end of applicator. by decreasing the applicator diameter, the mean energy of electron beam decreased. using applicators and increasing their size, x-ray contamination will increase. the percentage of x-ray contamination increases by applicator diameter. this is related to the increase of the mean energy of electron beams. conclusion: application of pmma collimator leads to, although well below accepted level, the production of bremsstrahlung. the results of this study showed that special design of liac head accompanying by pmma collimator system cause to produce an electron beam with an individual dosimetric characteristic making it a useful tool for intraoperative radiotherapy purposes. normal 0 false false false en-us x-none ar-sa
similar resources
Monte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator
Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...
full textDosimetric characteristics of electron beams produced by two mobile accelerators, Novac7 and Liac, for intraoperative radiation therapy through Monte Carlo simulation
The Novac7 and Liac are linear accelerators (linacs) dedicated to intraoperative radiation therapy (IORT), which produce high energy, very high dose-per-pulse electron beams. The characteristics of the accelerators heads of the Novac7 and Liac are different compared to conventional electron accelerators. The aim of this work was to investigate the specific characteristics of the Novac7 and Liac...
full textMonte Carlo Simulation of the Electron Beams Produced by a Linear Accelerator for Intra- Operative Radiation Therapy
In this work, organized as a short review, we present some results obtained by applying the Monte Carlo techniques in the Intra-Operative Radiation Therapy (IORT). The electron beams generated by the NOVAC7 IORT accelerator have been simulated using BEAMnrc/EGSnrc Monte Carlo code, the dose distributions and water-to-air stopping power ratios being later calculated with the associated software ...
full textRadiation survey around a Liac mobile electron linear accelerator for intraoperative radiation therapy
The aim of this study was to perform a detailed analysis of the air kerma values around a Liac mobile linear accelerator working in a conventional operating room (OR) for IORT. The Liac delivers electron beams at 4, 6, 8 and 10 MeV. A radiation survey to determine photon leakage and scatter consisted of air kerma measurements on a spherical surface of 1.5 m radius, centered on the titanium exit...
full textTotal skin electron therapy (TSET): Monte Carlo Simulation and implementation
Introduction: Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Operating procedures for total skin electron irradiation and its dosimetry vary in different radiation therapy centers in the world. In this article, validation of TSET techniq...
full textmonte carlo simulation of varian clinac 2100c electron beams
background: the purpose of this study was to investigate the application of the monte carlo technique to calculate and analysis of dosimetric parameters for electron beams used in radiotherapy. this technique is based on statistical method and has a powerful role in different radiotherapy aspects. materials and methods: the simulated medical linear accelerator was the varian clinac 2100c. the e...
full textMy Resources
Save resource for easier access later
Journal title:
journal of biomedical physics and engineeringجلد ۲۰۱۲، شماره ۱۲، صفحات ۰-۰
Hosted on Doprax cloud platform doprax.com