fast electrocatalytic determination of methimazole at an activated glassy carbon electrode

Authors

fahimeh jalali department of chemistry-razi university

zahra hatami department of chemistry razi university

abstract

a fast and simple voltammetric method for the determination of methimazole in pharmaceutical products was reported. a glassy carbon electrode was pretreated by anodization at +1.75 v (vs. sce) for 5 min, followed by potential cycling in the range of 0.3-1.3 v (20 cycles). the pretreated electrode showed an excellent electrocatalytic effect on the oxidation of methimazole. compared with untreated electrode, a large decrease (~300 mv) in the oxidation peak of methimazole was observed. the oxidation peak current at the new potential (0.4 v vs. sce) was linearly dependent on the concentration of methimazole in the range of 7.0 - 130 μm with a detection limit of 3.7 μm (s/n = 3). the method was successfully used in the determination of methimazole in thyramozol tablets. due to the simple and fast electrode preparation, there is no need for electrode cleaning or storage.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Fast electrocatalytic determination of methimazole at an activated glassy carbon electrode

A fast and simple voltammetric method for the determination of methimazole in pharmaceutical products was reported. A glassy carbon electrode was pretreated by anodization at +1.75 V (vs. SCE) for 5 min, followed by potential cycling in the range of 0.3-1.3 V (20 cycles). The pretreated electrode showed an excellent electrocatalytic effect on the oxidation of methimazole. Compared with untreate...

full text

Fast electrocatalytic determination of methimazole at an activated glassy carbon electrode

A fast and simple voltammetric method for the determination of methimazole in pharmaceutical products was reported. A glassy carbon electrode was pretreated by anodization at +1.75 V (vs. SCE) for 5 min, followed by potential cycling in the range of 0.3-1.3 V (20 cycles). The pretreated electrode showed an excellent electrocatalytic effect on the oxidation of methimazole. Compared with untreate...

full text

Fast Electrocatalytic Determination of Methimazole at an Activated Glassy Carbon Electrode

A fast and simple voltammetric method for the determination of methimazole in pharmaceutical products was reported. A glassy carbon electrode was pretreated by anodization at +1.75 V (vs. SCE) for 5 min, followed by potential cycling in the range of 0.3-1.3 V (20 cycles). The pretreated electrode showed an excellent electrocatalytic effect on the oxidation of methimazole. Compared with untreate...

full text

Electrocatalytic Determination of Isoniazid by a Glassy Carbon Electrode Modified with Poly (Eriochrome Black T)

In this work poly eriochrome black T (EBT) was electrochemically synthesized on the glassy carbon electrode as electrode modifier. On the modified electrode, voltammetric behavior of isoniazid (INH) was investigated. The poly (EBT)-modified glassy carbon electrode has excellent electrocatalytic ability for the electrooxidation of isoniazid. This fact was appeared as a reduced overpotential of I...

full text

Electrocatalytic Oxidation of Hydrazine at Epinephrine Modified Glassy Carbon Electrode (EPMGCE).

A thin film of epinephrine (EP) was electrochemically deposited on the surface of glassy carbon electrode previously activated in NaHCO3 solution. The cyclic voltammograms of the modified electrode indicate that the surface confined EP are strongly dependent on the solution pH, as expected for quinone/hydroquinone functionalities. The EP-modified glassy carbon electrode exhibited...

full text

Electrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode

A sensor, based on multi-wall carbon nanotubes modified glassy carbon electrode (MWCNT/GCE), was developed for determination of fenitrothion. Determining the surface area of MWCNT/GCE showed that this surface is three times more active than that of a glassy carbon electrode. The experimental parameters, such as the amount of MWCNTs, pH of the fenitrothion solution, preconcentration potential an...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of pharmaceutical research

جلد ۱۵، شماره ۴، صفحات ۷۳۵-۷۴۱

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023