athree-wavelength pulse oximeter for carboxyhemoglobin determination
Authors
abstract
pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. this paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (hbco), by unfiltered leds at 660 nm, 810 nm, and 940 nm. background information is given on the theory of pulse oximetry. theoretical approximations and calculations which are implemented in our instrument are presented. sensor design and a flowchart, showing the signal processing routine that accomplishes the required analysis is included. the problem of noise occurrence during the signal processing routine is also discussed.
similar resources
A Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination
Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...
full textA Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination
Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...
full textUse of a noninvasive pulse CO-oximeter to measure blood carboxyhemoglobin levels in bingo players.
BACKGROUND Though smokers are known to have elevated blood carboxyhemoglobin (COHb), due to inhalation of carbon monoxide (CO) in cigarette smoke, limited data exist regarding COHb levels in nonsmokers exposed to secondhand smoke. METHODS COHb was measured using a new noninvasive pulse CO-oximeter (Rad-57, Masimo, Irvine, California) in 38 subjects entering a bingo hall where smoking was allo...
full textThe measurement of carboxyhemoglobin and methemoglobin using a non-invasive pulse CO-oximeter.
The pulse CO-oximeter (Rad-57 Masimo Corporation, Irvine, CA) allows non-invasive and instantaneous measurement of carboxyhemoglobin (COHb) and methemoglobin (MetHb) percentage level using a finger probe. However, the accuracy and reliability of the Rad-57 against the gold standard of venous or arterial blood samples have not been clearly established. Thus, the objective of this trial is to eva...
full textPulse Oximeter Calibrator
........................................................................................................................................................ 5 Table of Figures ............................................................................................................................................ 6 Table of Tables .....................................................................
full textA Pulse Oximeter
The objective of this work was to develop a prototype for a pulse oximeter. Given the necessity, in most medical interventions, to monitorize Oxygen saturation in peripheral blood (SpO2) a pulse oximeter is highly necessary in any operating room or intensive care unit. The electronic device was built recurring mostly to Integrated Circuit (IC) and its control was performed via a programmed micr...
full textMy Resources
Save resource for easier access later
Journal title:
مهندسی برق و الکترونیک ایرانجلد ۵، شماره ۲، صفحات ۱-۷
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023