new coated graphite potentiometric sensor for selective determination of copper (ii) ions

Authors

arezoo ghaemi

zahra setareh

abstract

0

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

New Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions

A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...

full text

Polymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions

Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...

full text

polymeric membrane sensor for potentiometric determination of tin(ii) ions

tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...

full text

A potentiometric rhodamine-B based membrane sensor for the selective determination of chromium ions in wastewater.

The construction and performance characteristics of a novel chromate ion-selective membrane sensor are described and used for determining chromium(III) and chromium(VI) ions. The sensor is based on the use of a rhodamine-B chromate ion-associate complex as an electroactive material in a poly(vinyl chloride) membrane plasticized with o-nitrophenyloctyl ether as a solvent mediator. In a phosphate...

full text

New conventional coated-wire ion-selective electrodes for flow-injection potentiometric determination of chlordiazepoxide.

New chlordiazepoxide hydrochloride (Ch-Cl) ion-selective electrodes (conventional type) based on ion associates, chlordiazepoxidium-phosphomolybdate (I) and chlordiazepoxidium-phosphotungstate (II), were prepared. The electrodes exhibited mean slopes of calibration graphs of 59.4 mV and 60.8 mV per decade of (Ch-Cl) concentration at 25 degrees C for electrodes (I) and (II), respectively. Both e...

full text

Fabrication of new carbon paste electrodes based on gold nano-particles self-assembled to mercapto compounds as suitable ionophores for potentiometric determination of Copper ions

In the present study, we investigate the potentiometric behavior of Cu2+ carbon paste electrodes based on two mercapto compounds 2-Ethylmino-5-Mercapto-1,3,4-Thiadiazole (EAMT) and 2-Acetylamino-5-mercapto-1,3,4-thiadiazole (AAMT) self-assembled on gold nano-paricle (GNP) as ionophore. Then, the results obtained from the modified electrodes are compared. The self-assembled ionophores exhibit a ...

full text

My Resources

Save resource for easier access later


Journal title:
journal of applied chemical research

جلد ۱۱، شماره ۱، صفحات ۸۱-۹۴

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023