the effect of scattering from leg region on organ doses in prostate brachytherapy for 103pd, 125i and 131cs seeds

Authors

seyed milad vahabi energy engineering and physics department, amirkabir university of technology, tehran, iran

mojtaba shamsaei zafarghandi energy engineering and physics department, amirkabir university of technology, tehran, iran

abstract

introduction dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. three radioisotopes, namely, 125i, 103pd, and 131cs, are extensively used in this method. in this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the legs on dose calculations. materials and methods the doses to organs of interest were calculated using mcnpx code and ornl (oak ridge national laboratory) phantom. results doses to the prostate as a source of radiation for 125i, 103pd, and 131cs were approximately 108.9, 97.7, and 81.5 gy, respectively. bladder, sigmoid colon, and testes received higher doses than other organs due to proximity to the prostate. differences between the doses when tallying with the legs intact and with the legs voided were significant for testes, sigmoid colon contents, and sigmoid colon wall because of their proximity to the prostate. there was also a good consistency between our results and the data published by montefiore medical center and albert einstein college of medicine for the prostate. conclusion scattering from leg region had a significant effect on doses to testes, sigmoid colon contents, and sigmoid colon wall in the pelvic region, and prostate and the other organs were unaffected. brachytherapy treatment plans using 131cs seeds allow for better sparing of critical tissues, with a comparable number of, or fewer, seeds required, compared to 125i seeds.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

The Effect of Scattering from Leg Region on Organ Doses in Prostate Brachytherapy for 103Pd, 125I and 131Cs Seeds

Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the ...

full text

The Effect of Scattering from Leg Region on Organ Doses in Prostate

Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125 I, 103 Pd, and 131 Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for t...

full text

Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seeds

Background: A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC), is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet.Objective: The present study aims to modify source strength for different configurations of 125I and 103...

full text

Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd Seeds

BACKGROUND A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC) is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet. OBJECTIVE The present study aims to modify source strength for different configurations of 125I and 103Pd...

full text

New National Air-Kerma-Strength Standards for 125I and 103Pd Brachytherapy Seeds

The new U.S. measurement standard for the air-kerma strength from low-energy photon-emitting brachytherapy seed sources is formally described in detail. This instrument-based standard was implemented on 1 January 1999, with its salient features and the implications of differences with the previous standard given only through a series of informal communications. The Wide-Angle Free-Air Chamber (...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of medical physics

جلد ۱۳، شماره ۳، صفحات ۲۰۳-۲۱۰

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023