assessment of dose calculation accuracy of tigrt treatment planning system for physical wedged fields in radiotherapy

Authors

bagher farhood medical physics department, faculty of medicine, mashhad university of medical sciences, mashhad, iran

mohammad taghi bahreyni toossi medical physics research center, mashhad university of medical sciences, mashhad, iran

shokouhozaman soleymanifard medical physics research center, mashhad university of medical sciences, mashhad, iran

abstract

introduction wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (tps) is important. the objective of the present study was to quantify the dose calculation accuracy of tigrt tps for physical wedged fields in radiotherapy. materials and methods a semiflex™ ionization chamber was used for dose measurements in a water phantom; tigrt tps was also applied for dose calculations. the central axis (i.e., high dose-small dose gradient), build-up (i.e., high dose-large dose gradient), off-axis (i.e., high dose-small dose gradient), and out-of-field (i.e., low dose-small dose gradient) regions were evaluated in this study. finally, the confidence limit values were obtained to quantify the dose calculation accuracy of tps in these regions. results the confidence limit values for the central axis, build-up, off-axis, and out-of-field regions were 1.01, 8.62, 1.79, and 55.24, respectively. furthermore, the results showed that tigrt tps underestimated the dose of build-up and out-of-field regions for most points. conclusion according to the results of the present study, it can be concluded that the dose calculation accuracy of tigrt tps for physical wedged fields in the central axis, build-up, and off-axis regions is adequate, while it is insufficient for out-of-field regions.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Assessment of Dose Calculation Accuracy of TiGRT Treatment Planning System for Physical Wedged fields in Radiotherapy

Introduction Wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. Since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (TPS) is important. The objective ...

full text

Assessment of Dose Calculation Accuracy of TiGRT Treatment Planning System for Physical Wedged fields in Radiotherapy

Introduction Wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. Since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (TPS) is important. The objective ...

full text

Evaluation of Dose Calculation Accuracy of Isogray Treatment Planning System in Craniospinal Radiotherapy

Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...

full text

Dose calculations accuracy of TiGRT treatment planning system for small IMRT beamlets in heterogeneous lung phantom

Background: Accurate dose calculations in small beamlets and lung material have been a great challenge for most of treatment planning systems (TPS).  In the current study, the dose calculation accuracy of TiGRT TPS was evaluated for small beamlets in water and lung phantom by comparison to Monte Carlo (MC) calculations. Materials and Methods: The head of Siemens Oncor-impression linac...

full text

Evaluation of Three-dimensional Treatment Planning System (TPS) performance in dose calculation of virtual wedged fields using film dosimetry

Introduction: Nowadays radiotherapy plays an important role in cancer treatment. Different radiotherapy techniques improvement emphasizes on using of the precise ، appropriate and useful algorithms. one of these techniques are wedged which is used in radiotherapy to compensate missing tissues and create a uniform dose distribution in tissues. The Siemens Artiste linear accelera...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of medical physics

جلد ۱۳، شماره ۳، صفحات ۱۴۶-۱۵۳

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023