validating a stability indicating hplc method for kinetic study of cetirizine degradation in acidic and oxidative conditions
Authors
abstract
a stability indicating high-performance liquid chromatography (hplc) method wasvalidated and used to study the degradation of cetirizine dihydrochloride in acidic and oxidativeconditions. the separation was carried out on a symmetry c18 column and a mixture of 50 mmkh2po4 and acetonitrile (60:40 v/v, ph = 3.5) was used as the mobile phase. the method waslinear over the range of 1-20 μg/ml of cetirizine dihydrochloride (r2 > 0.999) and the withindayand between-day precision values were less than 1.5%. the results showed that cetirizinedihydrochloride was unstable in 2 m hcl and 0.5% h2o2. the kinetics of the acidic degradationshowed a pseudo-first-order reaction in the temperature range of 70-90°c. in addition, thekinetics of hydrogen peroxide mediated degradation was pseudo-first-order in the temperaturerange of 50-80°c.
similar resources
Validating a Stability Indicating HPLC Method for Kinetic Study of Cetirizine Degradation in Acidic and Oxidative Conditions
A stability indicating High-Performance Liquid Chromatography (HPLC) method wasvalidated and used to study the degradation of cetirizine dihydrochloride in acidic and oxidativeconditions. The separation was carried out on a Symmetry C18 column and a mixture of 50 mMKH2PO4 and acetonitrile (60:40 v/v, pH = 3.5) was used as the mobile phase. The method waslinear over the range of 1-20 μg/mL of ce...
full textValidating a Stability Indicating HPLC Method for Kinetic Study of Cetirizine Degradation in Acidic and Oxidative Conditions
A stability indicating High-Performance Liquid Chromatography (HPLC) method wasvalidated and used to study the degradation of cetirizine dihydrochloride in acidic and oxidativeconditions. The separation was carried out on a Symmetry C18 column and a mixture of 50 mMKH2PO4 and acetonitrile (60:40 v/v, pH = 3.5) was used as the mobile phase. The method waslinear over the range of 1-20 μg/mL of ce...
full textValidating a Stability Indicating HPLC Method for Kinetic Study of Cetirizine Degradation in Acidic and Oxidative Conditions
A stability indicating High-Performance Liquid Chromatography (HPLC) method was validated and used to study the degradation of cetirizine dihydrochloride in acidic and oxidative conditions. The separation was carried out on a Symmetry C18 column and a mixture of 50 mM KH2PO4 and acetonitrile (60:40 v/v, pH = 3.5) was used as the mobile phase. The method was linear over the range of 1-20 μg/mL o...
full texta stability indicating hplc method for determination of mebeverine in the presence of its degradation products and kinetic study of its degradation in oxidative condition
an hplc method for determination of mebeverine hydrochloride (mh) in the presence of its degradation products was developed. the degradation of mh was studied under hydrolysis, oxidative and photolysis stress conditions. under alkaline, acidic and oxidative conditions, degradation of mh was observed. the separation was performed using a symmetry c 18 column and a mixture of 50 mm kh 2 po 4 , ac...
full textKinetics study of metaxalone degradation under hydrolytic, oxidative and thermal stress conditions using stability-indicating HPLC method
An isocratic stability indicating RP-HPLC-UV method is presented for the determination of metaxalone (MET) in the presence of its degradation products. The method uses Dr. Maisch C18 column (250 mm×4.6 mm, 5 μm) with mobile phase consisting of acetonitrile-potassium dihydrogen orthophosphate buffer with 4 mL of 0.4% triethyl amine (pH 3.0; 10 mM) (58:42, v/v) at a flow rate of 1.0 mL/min. pH of...
full textA stability indicating HPLC method for determination of mebeverine in the presence of its degradation products and kinetic study of its degradation in oxidative condition
An HPLC method for determination of mebeverine hydrochloride (MH) in the presence of its degradation products was developed. The degradation of MH was studied under hydrolysis, oxidative and photolysis stress conditions. Under alkaline, acidic and oxidative conditions, degradation of MH was observed. The separation was performed using a Symmetry C18 column and a mixture of 50 mM KH2PO4, acetoni...
full textMy Resources
Save resource for easier access later
Journal title:
iranian journal of pharmaceutical researchجلد ۱۲، شماره ۲، صفحات ۲۸۷-۲۹۴
Hosted on Doprax cloud platform doprax.com