a highly sensitive kinetic spectrophotometric method for the determination of ascorbic acid in pharmaceutical samples
Authors
abstract
in this study, a new reaction system for quantitative determination of ascorbic acid was introduced. the developed method is based on inhibitory effect of ascorbic acid on the orange g-bromate system. the change in absorbance was followed spectrophotometrically at 478 nm. the dependence of sensitivity on the reaction variables including reagents concentration, temperature and time was investigated. under optimum experimental conditions, calibration curve was linear over the range 0.7 – 33.5 μg ml-1 of ascorbic acid including two linear segments and the relative standard deviations (n = 6) for 5.0 and 20.0 μg ml–1 of ascorbic acid were 1.08 and 1.02%, respectively. the limit of detection was 0.21 μg ml−1 of ascorbic acid. the effect of diverse species was also investigated. the developed method was successfully applied for the determination of ascorbic acid in pharmaceutical samples. the results were in a good agreement with those of reference method.
similar resources
A Highly Sensitive Kinetic Spectrophotometric Method for the Determination of Ascorbic Acid in Pharmaceutical Samples
In this study, a new reaction system for quantitative determination of ascorbic acid was introduced. The developed method is based on inhibitory effect of ascorbic acid on the Orange G-bromate system. The change in absorbance was followed spectrophotometrically at 478 nm. The dependence of sensitivity on the reaction variables including reagents concentration, temperature and time was investiga...
full textA Highly Sensitive Kinetic Spectrophotometric Method for the Determination of Ascorbic Acid in Pharmaceutical Samples
In this study, a new reaction system for quantitative determination of ascorbic acid was introduced. The developed method is based on inhibitory effect of ascorbic acid on the Orange G-bromate system. The change in absorbance was followed spectrophotometrically at 478 nm. The dependence of sensitivity on the reaction variables including reagents concentration, temperature and time was investiga...
full textA Highly Sensitive Kinetic Spectrophotometric Method for the Determination of Ascorbic Acid in Pharmaceutical Samples
In this study, a new reaction system for quantitative determination of ascorbic acid was introduced. The developed method is based on inhibitory effect of ascorbic acid on the Orange G-bromate system. The change in absorbance was followed spectrophotometrically at 478 nm. The dependence of sensitivity on the reaction variables including reagents concentration, temperature and time was investiga...
full textKINETIC DETERMINATION OF ASCORBIC ACID a WITH SPECTROPHOTOMETRIC DETECTION
A simple and rapid method has been developed for the determination of ascorbic acid in fruit and pharmaceutical products. The method is based on the measurement of the reaction rate between ammonium molybdate and ascorbic acid in acidic media. The reaction was monitored spectrophotometrically at 800 nm by fixed-time and variable-time methods. The calibration graph was linear in the range of...
full textKinetic Spectrophotometric Determination of Morphine in Pharmaceutical Samples
A new, sensitive, simple, inexpensive and fast kinetic spectrophotometric method was developed for the determination of trace amounts of morphine over the range of 12-60ng/mL. The method is based on the catalytic effect of morphine on the reaction of bromate and methylene bluein acidic media is reported. The reaction was monitored spectrophotometrically by 60 ng/ml measuring the decrease in abs...
full textkinetic determination of ascorbic acid a with spectrophotometric detection
a simple and rapid method has been developed for the determination of ascorbic acid in fruit and pharmaceutical products. the method is based on the measurement of the reaction rate between ammonium molybdate and ascorbic acid in acidic media. the reaction was monitored spectrophotometrically at 800 nm by fixed-time and variable-time methods. the calibration graph was linear in the range of 5 0...