comparison of different linear filter design methods for handling ocular artifacts in brain computer interface system

Authors

sahar seifzadeh

faculty of computer and information technology engineering, qazvin branch, islamic azad university, qazvin, iran karim faez

electrical engineering department, amirkabir university of technology tehran, iran mahmood amiri

medical biology research centre, kermanshah university of medical sciences, kermanshah, iran

abstract

brain-computer interfaces (bci) record brain signals, analyze and translate them into control commands which are relayed to output devices that carry out desired actions. these systems do not use normal neuromuscular output pathways. actually, the principal goal of bci systems is to provide better life style for physically-challenged people which are suffered from cerebral palsy, amyotrophic lateral sclerosis, stroke, or spinal cord injury. one of the focal points in brain-computer interface (bci) systems is physiological artifacts handling. physiological artifacts such as electrooculography (eog) and electrooculography (emg) are considered among the most important sources of physiological artifacts in bci systems. pre-processing is considerable step by means of next steps such as feature extraction and classification that we need clean signals without undesirable artifacts to have better classification rate. using a linear filter to remove these artifacts is like a dime a dozen due to their acceptable results in recent bci pre-processing researches. although this method has different options, forasmuch as the mu (8–13 hz) and beta (16–25 hz) frequency bands play a key role in classification of motor imagery we have decided to design two band pass filters with elliptic and  butterworth  infinite impulse response designing methods in 8 to 40 hz frequencies. our results in graz 2a dataset in bci competition iv indicates that, elliptic band-pass filter has better performance for eog removing in this specific dataset.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Comparison of Different Linear Filter Design Methods for Handling Ocular Artifacts in Brain Computer Interface System

 Brain-computer interfaces (BCI) record brain signals, analyze and translate them into control commands which are relayed to output devices that carry out desired actions. These systems do not use normal neuromuscular output pathways. Actually, the principal goal of BCI systems is to provide better life style for physically-challenged people which are suffered from cerebral palsy, amyotrophic l...

full text

A Study of Various Feature Extraction Methods on a Motor Imagery Based Brain Computer Interface System

Introduction: Brain Computer Interface (BCI) systems based on Movement Imagination (MI) are widely used in recent decades. Separate feature extraction methods are employed in the MI data sets and classified in Virtual Reality (VR) environments for real-time applications. Methods: This study applied wide variety of features on the recorded data using Linear Discriminant Analysis (LDA) classifie...

full text

Comparison of Four Classification Methods for Brain-computer Interface

This paper examines the performance of four classifiers for Brain Computer Interface (BCI) systems based on multichannel EEG recordings. The classifiers are designed to distinguish EEG patterns corresponding to performance of several mental tasks. The first one is the basic Bayesian classifier (BC) which exploits only interchannel covariance matrices corresponding to different mental tasks. The...

full text

Comparison of Linear Classification Methods for P300 Brain-computer Interface on Disabled Subjects

In this paper, we investigate the accuracy of linear classification techniques for a P300 Brain-Computer Interface used in a typing paradigm. Fisher’s Linear Discriminant Analysis (LDA), Bayesian Linear Discriminant Analysis (BLDA), Stepwise Linear Discriminant Analysis (SLDA), linear Support Vector Machine (SVM) and a method based on Feature Extraction (FE) were compared. Experiments were perf...

full text

a study of various feature extraction methods on a motor imagery based brain computer interface system

introduction: brain computer interface (bci) systems based on movement imagination (mi) are widely used in recent decades. separate feature extraction methods are employed in the mi data sets and classified in virtual reality (vr) environments for real-time applications. methods: this study applied wide variety of features on the recorded data using linear discriminant analysis (lda) classifier...

full text

Development of a Brain Computer Interface (BCI) Speller System Based on SSVEP Signals

BCI is one of the most intriguing technologies among other HCI systems, mostly because of its capability of recording brain activities. Spelling BCIs, which help paralyzed people to maintain communication, are one of the striking topics in the field of BCI. In this scientific a spelling BCI system with high transfer rate and accuracy that uses SSVEP signals is proposed.In addition, we suggested...

full text

My Resources

Save resource for easier access later


Journal title:
journal of computer and robotics

جلد ۷، شماره ۱، صفحات ۵۱-۵۶

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023