preconcentration of pb(ii) by graphene oxide with covalently linked porphyrin adsorbed on surfactant coated c18 before determination by faas
Authors
abstract
a simple, highly sensitive, accurate and selective method for determination of trace amounts of pb(ii) in water samples is presented. a novel graphene oxide with covalently linked porphyrin solid-phase extraction adsorbent was synthesized by covalently linked porphyrin onto the surfaces of graphite oxides. the stability of a chemically (go-h2p) especially in concentrated hydrochloric acid was studied which used as a recycling and pre-concentration reagent for further uses of (go-h2p). the method is based on (go-h2p) of pb(ii) on surfactant coated c18, modified with a porphyrin-treated graphite oxides (go-h2p). the retained ions were then eluted with 4 ml of 4 m nitric acid and determined by flame atomic absorption spectrometry (faas) at 283.3 nm for pb. the influence of flow rates of sample and eluent solutions, ph, breakthrough volume, effect of foreign ions on chelation and recovery were investigated. 1.5 g of surfactant coated c18 adsorbs 40 mg of the schiff's base which in turn can retain 15.2 ± 0.8 mg of each of the two ions. the limit of detection (3σ) for pb(ii) was found to be 3.20 ng l-1. the enrichment factor for both ions is 100. the mentioned method was successfully applied on determination of lead in different water samples. the ions were also speciated by means of three columns system.
similar resources
Preconcentration of Pb(II) by Graphene Oxide with Covalently Linked Porphyrin Adsorbed on Surfactant Coated C18 before Determination by FAAS
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Pb(II) in water samples is presented. A novel Graphene oxide with covalently linked porphyrin solid-phase extraction adsorbent was synthesized by covalently linked porphyrin onto the surfaces of graphite oxides. The stability of a chemically (GO-H2P) especially in concentrated hydrochloric acid was s...
full textPreconcentration of Pb(II) by Graphene Oxide with Covalently Linked Porphyrin Adsorbed on Surfactant Coated C18 before Determination by FAAS
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Pb(II) in water samples is presented. A novel Graphene oxide with covalently linked porphyrin solid-phase extraction adsorbent was synthesized by covalently linked porphyrin onto the surfaces of graphite oxides. The stability of a chemically (GO-H2P) especially in concentrated hydrochloric acid was s...
full textExtraction of Co(II) by Isocyanate Treated Graphite Oxides (iGOs) Adsorbed on Surfactant Coated C18 Before Determination by FAAS
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Co(II) in water samples is presented. Isocyanate treated graphite oxides (iGOs) solid phase extraction adsorbent was synthesized by covalently isocyanate onto the surfaces of graphite oxides. The stability of a chemically (iGOs) especially in concentrated hydrochloric acid which was then used as a re...
full textExtraction of Co(II) by Isocyanate Treated Graphite Oxides (iGOs) Adsorbed on Surfactant Coated C18 Before Determination by FAAS
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Co(II) in water samples is presented. Isocyanate treated graphite oxides (iGOs) solid phase extraction adsorbent was synthesized by covalently isocyanate onto the surfaces of graphite oxides. The stability of a chemically (iGOs) especially in concentrated hydrochloric acid which was then used as a re...
full textExtraction and separation of Ni(II) from by functionalized graphene oxide with covalently linked porphyrin (GO–H2NP) adsorbed on surfactant coated C18
A novel, simple, sensitive and effective method has been developed for preconcentration of Ni (II) on functionalized Graphene oxide with covalently linked porphyrin (GO–H2NP) solid-phase extraction adsorbent. The stability of a chemical (GO–H2NP), especially in concentrated hydrochloric acid, was then used as a recycling and pre-concentration reagent. The method is based on selective chelation ...
full textextraction of co(ii) by isocyanate treated graphite oxides (igos) adsorbed on surfactant coated c18 before determination by faas
a simple, highly sensitive, accurate and selective method for determination of trace amounts of co(ii) in water samples is presented. isocyanate treated graphite oxides (igos) solid phase extraction adsorbent was synthesized by covalently isocyanate onto the surfaces of graphite oxides. the stability of a chemically (igos) especially in concentrated hydrochloric acid which was then used as a re...
full textMy Resources
Save resource for easier access later
Journal title:
international journal of bio-inorganic hybrid nanomaterialsجلد ۲، شماره ۲، صفحات ۳۵۵-۳۶۴
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023