dental tissue as a tld dosimeter

Authors

m. mirzaii m. mirzaii; nuclear research center for agriculture and medicine (nrcam) p.o.box: 31585-4395 karaj-iran fax : +98-261- 4411106,

h. afarideh

s.m. haji-saeid

g.r. aslani

abstract

background: thermoluminescence dosimetry is one of the dosimetry procedures used widely as routine and personal dosimeters. in order to extend this kind of dosimeters, dental tissue has been examined and was found promising as a tld dosimeter. materials and methods : in this study, 70 health teeth were collected. the only criterion, which was considered for selection of the teeth, was the healthiness of them regardless of age and gender of the donors. all collected samples were washed and cleaned and milled uniformly. the final powder had a uniform grain size between 100 – 300 micrometer. the sample was divided into four groups. group a and b were used for measurement of density and investigation of variation of thermoluminescent characteristics with temperature respectively. groups c and d were used for investigation of variation of thermoluminescent intensity with dose and fading of this intensity with time . in all cases the results obtained with dental tissue were compared to a standard lif, tld dosimeter. results : it was found that, average density of the dental tissue was 1.570 g/cm3, which is comparable to density of lif, which is 1.612 g/cm3. it was also concluded that the range of 0-300 oc, dental tissue has a simple curve with two specific peaks at 140 and 250 oc respectively. the experiment also showed that, the variation of relative intensity versus dose is linear in the range of 0.04 – 0.1gy . the fading rate of dental tissue is higher than lif but still in the acceptable range (14% per month in compare to 5.2% per month) conclusion : dental tissue as a natural dosimeter is comparable with tld and can be used in accidental events with a good approximation . iran . j. radiat. res. 2003 1(2): 113 – 117.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Dental tissue as a TLD dosimeter

Background: Thermoluminescence dosimetry is one of the dosimetry procedures used widely as routine and personal dosimeters. In order to extend this kind of dosimeters, dental tissue has been examined and was found promising as a TLD dosimeter. Materials and Methods : In this study, 70 health teeth were collected. The only criterion, which was considered for selection of the teeth, was the healt...

full text

The use of LiF (TLD‐100) as an out‐of‐field dosimeter

The commonly used thermoluminescent dosimeter TLD-100 (Harshaw Chemical Company, Solon, OH) responds not only to photons and electrons, but also to neutrons that are produced during high-energy therapies. As a result, TLD-100 measurements outside of the treatment field are suspect when high-energy radiation is used. Although alternatives such as TLD-700 do not respond to neutrons, specialty dos...

full text

Achievement of Quality Control Parameters for NIS Personal Thermoluminescence Dosimeter (TLD) System

This work intend to identify and follow up quality control parameters to improve thermoluminescence dosemeter (TLD) system used for personal dosimetry in ionizing radiation metrology laboratory (IRML). Characterization of personal dosimetry system has presented in terms of the stability of reader calibration factors, linearity of response for Cs as reference radiation source, energy and angular...

full text

Principles and methods of dental nerve tissue regeneration : a review

Background and Aim  Today, tissue engineering is considered a significant approach in modern medicine, which is why research in biomaterials has focused on the development of advanced scaffolding for regenerative medicine.  Many natural and synthetic polymers with a variety of origins have been used to make these scaffolds or are recommended by researches. These compositions usually have the pr...

full text

Recovery of thermoluminescence sensitivity in CaF2:Mn (TLD-400) dosimeter under heating process

In order to recovery the thermoluminescence (TL) sensitivity of CaF2:Mn (TLD-400) thermoluminescent dosimeter it was exposed to high gamma radiation dose of 10kGy, then by applying standard annealing followed by irradiation to 1Gy gamma dose, the TL signal was recorded . The TL response reduced due to the damage effect of high dose irradiation in comparison with control dosimeter with received ...

full text

Investigations on BeO as a dosimeter material for hadron therapy

Hadron cancer-therapy with high-energetic heavy-ions (HI) as available at the SIS facility at GSI Darmstadt [1] as well as the research with beams stopped in biological material as realized at the UNILAC at GSI in general require the precise knowledge of the applied dose within less than 1% in most cases. Solid state detectors based on various materials read out via thermally stimulated light e...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of radiation research

جلد ۱، شماره ۲، صفحات ۱۱۳-۱۱۷

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023