the need for national diagnostic reference levels: entrance surface dose measurement in intraoral radiography
Authors
abstract
background: intraoral radiographies are the most frequent x-ray examinations in humans. according to international commission on radiation protection (icrp) recommendations, the selection of a diagnostic reference level (drl) should be specific to a country or region. critica l organs such as thyroid gland are exposed to x-rays in intraoral radiography and these exposures should be kept as low as reasonably achievable. to assist the development of drls for intraoral radiography, a national radiation protection department-sponsored pilot study was carried out. materials and methods: thermoluminescent dosimetry (tld) is widely acknowledged to be the recommended method for measuring entrance surface doses (esd). in this study, esd was measured using lif thermoluminescent dosimeters (tld-100) on the skin (either mandibular or maxillary arcs) of 40 patients. three tld chips were placed on the skin of each patient. the doses were averaged for each radiography and mean esd of all patients calculated. results: the mean ± sd entrance surface dose at the center of the beam on the patients' skin in intraoral radiography was 1.173 ± 0.606 mgy (ranged from 0.01 to 0.40 mgy). the mean esd for male and female patients were 1.380 ± 0.823, and 1.004 ± 0.258 respectively. no statistically significant difference was found between these means. despite its necessity, in national level, there is no published data on the diagnostic reference levels for intraoral radiography. however, the results obtained in this study are lower than those reported by investigators in other countries. conclusion: in ir iran, due to lack of large scale studies, no diagnostic reference levels have been set for x-ray diagnostic procedures. due to lack of national diagnostic reference levels, it is not possible to clarify whether in intraoral radiographies any dose reduction techniques are needed. we intend to perform similar nationwide studies to set the diagnostic reference level for intraoral radiography. iran . j. radiat. res., 2004 2 (3): 127-133
similar resources
The need for national diagnostic reference levels: Entrance surface dose measurement in intraoral radiography
Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection (ICRP) recommendations, the selection of a diagnostic reference level (DRL) should be specific to a country or region. Critica l organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low ...
full textPaediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran
Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. <...
full textEntrance surface dose measurement on the thyroid gland in orthopantomography: The need for optimization
Background: The anatomic position and proven radiosensitivity of the thyroid make it an organ of concern in dental X-ray examinations. A National Radiation Protection Department (NRPD)-sponsored pilot study carried out in the Dental Radiology Department of RUMS., to assess if the radiation dose in panoramic radiographies could be reduced without significant impairment of the subjective image qu...
full textDiagnostic reference levels in intraoral dental radiography in Korea
PURPOSE The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. MATERIALS AND METHODS One hundred two intraoral dental radiographic machines from all regions of South Korea were selected...
full textentrance surface dose measurement on the thyroid gland in orthopantomography: the need for optimization
background: the anatomic position and proven radiosensitivity of the thyroid make it an organ of concern in dental x-ray examinations. a national radiation protection department (nrpd)-sponsored pilot study carried out in the dental radiology department of rums., to assess if the radiation dose in panoramic radiographies could be reduced without significant impairment of the subjective image qu...
full textDiagnostic reference levels at intraoral and dental panoramic examinations
Background: The aim of this study was to measure and determine diagnostic reference levels (DRLs) of programs used at intraoral and dent panoramic examinations in Kosovo. Materials and Methods: To determine DRL, were performed measurements for dose area product (DAP) at intraoral and dental panoramic radiology systems. This study has covered over 47% of X-ray units, which are in use for intraor...
full textMy Resources
Save resource for easier access later
Journal title:
iranian journal of radiation researchجلد ۲، شماره ۳، صفحات ۱۲۷-۱۳۳
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023