brachytherapy polymer gel dosimetry with xct

Authors

mahbod sedaghat department of medical physics, tehran university of medical sciences, tehran, iran

m.h. zahmatkesh

r. jaberi

sh. akhlaghpoor

abstract

abstractbackground: polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. in the current work, we present our preliminary results of investigating capability of x-ray ct for extracting brachytherapy dose distributions from a normoxic gel dosimeter. materials and methods: a normoxic radiosensitive polymer gel was fabricated under normal atmospheric conditions and poured into three phantoms. using cs137 brachytherapy sources, the phantoms were irradiated with different dose distributions with a ldr selectron remote after-loader. to improve snr, 25 images were obtained of each slice for image averaging and an averaged background image of an un-irradiated gel phantom was then subtracted for artifact removal. to further improve the accuracy, a self-consistent normalized method was used for calibration of the dosimeters based on an assumption of a linear dose response between zero and maximum dose regions in the gel. results: although results reveal very similar ct-number gradients to that of brachytherapy dose distributions, but the method does not fulfill brachytherapy dosimetry requirements. this might be due to the high prescribed doses in this study which in turn results in a large change in the ct numbers. this change in the ct numbers of the images can not be considered to have a linear relationship with dose which was the basic assumption of our calibration method, so the results are just qualitatively comparable. conclusion: in this study, the results of using x-ray ct for brachytherapy polymer gel dosimetry is promising but not still satisfying. improving a proper calibration method for correlating ct numbers to dose will be significantly helpful for performing measurements with ct. the main limitation for ct is still a low signal to noise ratio especially in lower dose areas.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Brachytherapy polymer gel dosimetry with xCT

ABSTRACTBackground: Polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. Research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. In the current work, we present our preliminary results of investigating capability of X-r...

full text

Comparison of the Obtained Results from Two Calibration Methods in MRI Brachytherapy Normoxic Polymer Gel Dosimetry

Introduction: Despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. In the current work, the feasibility of using a normoxic polymer gel dosimeter named MAGICA has been investigated for use in our clinical brachytherapy applic...

full text

comparison of the obtained results from two calibration methods in mri brachytherapy normoxic polymer gel dosimetry

introduction: despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. in the current work, the feasibility of using a normoxic polymer gel dosimeter named magica has been investigated for use in our clinical brachytherapy applic...

full text

Dosimetry in HDR brachytherapy with Fricke-gel layers and Fricke-gel catheters

Fricke-gel layer dosimeters (FGLD) and Fricke gel dosimetric catheters (FGDC) have been designed and tested with the aim of enquiring their suitability for HDR Ir brachytherapy source control and for in-vivo dose verification during treatment. Anisotropy function measurements have been carried out with FGLDs in which a thin plastic tube has been placed in for the Ir source insertion. FGDCs are ...

full text

Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification.

A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed to a 6 MV photon beam and the depth dose was compared against a diamond detecto...

full text

Uncertainty Analysis in MRI-based Polymer Gel Dosimetry

Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of radiation research

جلد ۳، شماره ۳، صفحات ۱۰۱-۱۰۸

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023