entrance surface dose measurements for routine x-ray examinations in chaharmahal and bakhtiari hospitals

Authors

d. shahbazi-gahrouei department of medical physics and medical engineering, isfahan university of medical sciences, isfahan, iran

abstract

background: there is not any report on the radiation doses received by patients in diagnostic radiology sections in hospitals under control of chaharmahal and bakhtiari medical sciences university, in the south west of iran. objectives: the aim of this study is measurement of entrance surface doses (esd) for the most routine types of x-ray procedures in radiology centers as part of ongoing dose reduction program. materials and methods: geiger-muller and thermoluminescence dosimeters (tld), were used to measure entrance surface doses for four common radiographic views in six hospitals (7 x-ray machines). the entrance surface dose was measured on 20 randomly selected patients (male and female) for each x-ray examination. patients were not exposed to any additional radiation and the radiographs were used for diagnostic purposes. results: the entrance surface doses for the pa and lateral chest x-ray examinations were found to be in the range of 0.22-1.45 and 0.34-4.90 mgy, respectively. the esd values for the ap or pa skull and lat skull were in the rage of 2.55-8.45 and 2.85-9.12 mgy, respectively. most of the esd measured doses were slightly greater than the icrp and nrpb reference doses. conclusions: the results of the present study indicate a need for quality assurance (qa) programs to be undertaken to avert considerable cost and high patient doses. the recommendations to avoid unnecessary radiation exposure are also given without lose of image quality.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Entrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals

Background: There is not any report on the radiation doses received by patients in diagnostic radiology sections in hospitals under control of Chaharmahal and Bakhtiari Medical Sciences University, in the south west of Iran. Objectives: The aim of this study is measurement of entrance surface doses (ESD) for the most routine types of X-ray procedures in radiology centers as part of ongoing d...

full text

Entrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals

Over the past hundred years or so, X-rays have been used for diagnostic purposes. The use of X-rays for imaging purposes, however, exposes patients to ionizing radiation. The increasing use of X-ray in hospitals has made medical exposure an important source of radiation in the population collective dose (1, 2). Ionizing radiation has the ability to break apart biologically important molecules s...

full text

Patient dose in routine X-ray examinations in Yazd state

Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...

full text

Radiation Dose Measurements in Routine X ray Examinations

The aim of current study was to evaluate patient's radiation dose in routine X-ray examinations in Omdurman teaching hospital Sudan.110 patients was examined (134) radiographs in two X-ray rooms. Entrance surface doses (ESDs) were calculated from patient exposure parameters using DosCal software. The mean ESD for the chest, AP abdomen, AP pelvis, thoracic spine AP, lateral lumber spine , antero...

full text

patient dose in routine x-ray examinations in yazd state

background: medical x-rays are the largest man-made source of public exposure to ionizing radiation. it is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. materials and methods: the entrance skin exposure (ese) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. the eses we...

full text

Assessment of Patients’ Entrance Skin Dose from Diagnostic X-ray Examinations at Public Hospitals of Akwa Ibom State, Nigeria

Introduction High doses of ionizing radiation can lead to adverse health outcomes such as cancer induction in humans. Although the consequences are less evident at very low radiation doses, the associated risks are of societal importance. This study aimed at assessing entrance skin doses (ESDs) in patients undergoing selected diagnostic X-ray examinations at public hospitals of Akwa Ibom State,...

full text