monte carlo and experimental relative dose determination for an iridium-192 source in water phantom

Authors

a.a. mowlavi physics department, school of sciences, sabzevar tarbiat moallem university, sabzevar, iran

f. cupardo servizio di fisica sanitaria, ospedali riuniti di trieste, trieste, italy

m. severgnini servizio di fisica sanitaria, ospedali riuniti di trieste, trieste, italy

abstract

background: monte carlo and experimental relative dose determination in a water phantom, due to a high dose rate (hdr) 192ir source is presented for real energy spectrum and monochromatic at 356 kev. materials and methods: the dose distribution has been calculated around the 192ir located in the center of 30 cm ×30 cm ×30 cm water phantom using mcnp4c code by monte carlo method. relative dose variation has been measured by using gafchromic rtqa along x and y axis, as well. percentage depth dose (pdd) variation along the different axis parallel and perpendicular the source were calculated. finally, f (5cm, θ|) dosimetry parameters of tg-43 protocol were determined. results: the results showed that the monte carlo method could calculate dose deposition in high gradient region, near the source, accurately. the isodose curves and dosimetric characteristics obtained for 192ir source are in good agreement with experimental results. conclusion: the isodose curves of the 192ir source were derived form dose calculation by mcnp code. also, monte carlo and experimental pdd x=2.5 mm are in good agreement, and the both results y=10 mm, in ||x [-25mm,25mm] interval were well matched. however, out of this range monte carlo result was estimated to be lower. the calculated dosimetry parameters for the source were in agreement with other results. iran. j. radiat. res., 2008 6 (1): 37-42

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Monte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom

Background: Monte Carlo and experimental relative dose determination in a water phantom, due to a high dose rate (HDR) 192Ir source is presented for real energy spectrum and monochromatic at 356 keV. Materials and Methods: The dose distribution has been calculated around the 192Ir located in the center of 30 cm ×30 cm ×30 cm water phantom using MCNP4C code by Monte Carlo method. Relati...

full text

Monte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom

Theoretical and experimental studies have been applied for dosimetric parameters determination of the brachytherapy sources (1-3). Usually, Monte Carlo method has been used to define such quantities as the anisotropy dose function, the radial dose function, and the dose calculation close to the source in brachytherapy (4-6). Ir source is used widely in brachytherapy to treat localized tumors ne...

full text

Monte Carlo Dose Calculation of 90 Sr/ 90 Y Source in Water Phantom

Introduction:  90 Sr/ 90 Y source  has  been  used  for  the  intravascular  brachytherapy  to  prevent  coronary  restenosis in the patients who have undergone angioplasty. The aim of this research is to determine the  dose distribution of  90 Sr/ 90 Y source in a water phantom.  Materials  and  Methods:  In  the  present  work,  MCNP  code  has  been  applied  to  calculate  the  dose  distri...

full text

Dosimetric investigation of high dose rate Ir-192 source with Monte Carlo method

Background: This study aims to calculate the air-kerma strength (SK), the dose rate constant (∧) and the dose rate profiles of a Gammamed 12i Ir-192 source by using the Monte Carlo technique and to compare the dose rate values with those calculated by the Abacus HDR treatment planning system (TPS). Materials and Methods: Air-kerma strength (in units of U; 1 U= μGy m2 h-1) and the dose ra...

full text

Comparison of Calibration Methods for an Iridium 192 Source (hdr) and Application to the Absorbed Dose to Water Determination

The aim of this study was to compare the high dose rate (HDR) iridium 192 source calibration in terms of reference air kerma rate with two types of ionisation chambers (a thimble chamber and a well-type chamber). Dose measurements in water have been also performed with thimble chamber and thermoluminescent dosimeters (TLD) in order to validate the absorbed dose to water calculation provided by ...

full text

monte carlo dose calculation of 90 sr/ 90 y source in water phantom

introduction:  90 sr/ 90 y source  has  been  used  for  the  intravascular  brachytherapy  to  prevent  coronary  restenosis in the patients who have undergone angioplasty. the aim of this research is to determine the  dose distribution of  90 sr/ 90 y source in a water phantom.  materials  and  methods:  in  the  present  work,  mcnp  code  has  been  applied  to  calculate  the  dose  distri...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of radiation research

جلد ۶، شماره ۱، صفحات ۳۷-۴۲

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023