a monte carlo simulation and dosimetric verification of physical wedges used in radiation therapy
Authors
abstract
background: the presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. material and methods: in this study the mcnp-4c monte carlo code was used to simulate the 9 mv photon beam generated by a linear accelerator. upon getting a good agreement between the monte carlo simulated and measured dose distribution in open fields, the model was used to simulate the physical wedges. the steel wedges with angles from 15º-60º were modeled and the primary and the secondary photon beams were calculated. the beam profiles and wedges factors were calculated for each wedge. the output factors were determined for 45 wedge. the calculated data were compared with the measured values of the same parameters. results: the results showed that the use of wedges reduced the fluencies of the primary and scattered photons and also increased the average energy of the primary and the scattered photons. the agreement between the calculated and the measured data was better than 2% for all wedges. the results also showed that as the wedge angle increased, the electron contamination of photon beam decreased. conclusion: the presence of a wedge in a 9 mv photon beam alters the primary and the scattered components generated by a linear accelerator. the simulated linac machine and its associated data can be used to predict the dose distribution in other complex fields. iran. j. radiat. res., 2010 7 (4): 223-227
similar resources
A Monte Carlo simulation and dosimetric verification of physical wedges used in radiation therapy
Background: The presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. Material and Methods: In this study the MCNP-4C Monte Carlo code was used to simulate the 9 MV photon beam generated by a linear accelerator. Upon getting a good agreement bet...
full textMonte Carlo study on beam hardening effect of physical wedges
Background: Physical wedges are still widely used as beam modifiers in external beam radiotherapy. However the presence of them in the beam trace may cause beam hardening which may not be considered in many treatment planning systems. The aim of this study is to investigate the beam hardening effect generated by physical wedges via different beam quality indexes as photon spectrum, half value l...
full textEnhancing and verification of dose in external radiation therapy using Gd nanoparticles as a theranostic agent: A Monte Carlo simulation study
Introduction: Theranostics, in particular, the use of radionuclides with the capability of simultaneous imaging and treatment has opened new horizons in personalized treatment planning of targeted radiation therapy. In this approach, positive beta or gamma emitters are required for imaging and alpha, beta and Auger electrons for treatment purpose. On the other hand, studies hav...
full textDosimetric analysis for the selection of radionuclides in bone pain palliation targeted therapy: A Monte Carlo simulation
Introduction:The use of beta emitters is one of the effective methods for palliation of bone metastasis. The risk of normal tissue toxicity should be evaluated in the bone pain palliation treatment. Methods: In this study, the Monte Carlo simulation code MCNPX was used for simulation a bone phantom model consisted of bone marrow, bone and soft tissue. Spe...
full textMonte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy
Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...
full textmonte carlo study on beam hardening effect of physical wedges
background: physical wedges are still widely used as beam modifiers in external beam radiotherapy. however the presence of them in the beam trace may cause beam hardening which may not be considered in many treatment planning systems. the aim of this study is to investigate the beam hardening effect generated by physical wedges via different beam quality indexes as photon spectrum, half value l...
full textMy Resources
Save resource for easier access later
Journal title:
iranian journal of radiation researchجلد ۷، شماره ۴، صفحات ۲۲۳-۲۲۷
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023