evaluation of depth dose characteristics of superficial x-rays machine using different kvp and applicators diameter

Authors

m. ismail department of physics, the islamia university of bahawalpur, bahawalpur, pakistan

m. afzal department of physics, the islamia university of bahawalpur, bahawalpur, pakistan

m. nadeem bahawalpur institute of nuclear medicine and oncology (bino), bahawalpur, pakistan

a.m. rana department of physics, bahauddin zakariya university, multan, pakistan

abstract

background: radiotherapy treatment planning requires different dosimetric quantities as input in order to calculate a desired dose distribution. this study has been focused to evaluate the depth dose characteristics of superficial x-rays being used for radiotherapy treatment. materials and methods: computerized 3-d water phantom of multi-data system was used. the measurements were made through ptw (physikalirsch-technische werkstalten) farmer type nt-30006 waterproof ionization chamber of 0.6cc, and ptw electrometer for digital dose rate reading in gy/min using five different diameter applicators and filters at five different values of accelerating potentials (kvps). results: the dose rate at various kvp x-ray beams was observed to decrease significantly with increasing depth in water phantom for all applicator diameters from 98% (at 0.1cm depth) down to 43% (at 2cm i.e. reference condition). the dose rate increases by increasing the value of kvp with a maximum at 150 kvp (1.6 and 0.93 gy/ min for respective applicator diameters 2.5cm and 10cm). applicator with 2.5cm diameter demonstrates better dose rate at 85kvp at different depths. pdd decreases lower than 50% for all combination of applicators and kvps at/or above 2cm depth so these measurements should not be considered for treatment planning. conclusion: higher energy x-rays are suggested to be used for applicators of higher diameters and smaller energy x-rays for applicators having smaller diameters. iran. j. radiat. res., 2011 9(3): 159-166

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Evaluation of depth dose characteristics of superficial X-rays machine using different kVp and applicators diameter

Background: Radiotherapy Treatment Planning requires different dosimetric quantities as input in order to calculate a desired dose distribution. This study has been focused to evaluate the depth dose characteristics of superficial X-rays being used for radiotherapy treatment. Materials and Methods: Computerized 3-D water phantom of multi-data system was used. The measurements were made...

full text

Evaluation of depth dose characteristics of superficial X-rays machine using different kVp and applicators diameter

*Corresponding author: Muhammad Ismail, Department of Physics, Bahauddin Zakariya University, Multan, 60800-Pakistan. E-mail: [email protected] Background: Radiotherapy Treatment Planning requires different dosimetric quantities as input in order to calculate a desired dose distribution. This study has been focused to evaluate the depth dose characteristics of superficial X-rays being use...

full text

hazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures

شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...

comparative dna interaction studies of antiviral drug, zidovudine and its complex using different instrumental methods

هدف از این مطالعه بررسی امکان استفاده از داروهای شناخته شده در درمان سایر بیماریها به عنوان داروهای ضد سرطان است. همچنین با استفاده از این داروها در ساختمان کمپلکس فلز می توان شاخص های دارویی بدست آمده را بررسی نمود. داروی ضد ویروس ایدز(hiv)به نام زیدوودین(azt)انتخاب و.کمپلکس.محلول.در.آب[pt(azt)2]cl2سنتزو به روشهای مختلف فیزیکی و شیمیایی شناسایی گردید. بر هم کنش مقایسه ای این دارو و کمپلکس پلا...

15 صفحه اول

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

Evaluation of a systemic change of Superficial X-ray tube characteristics

Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of radiation research

جلد ۹، شماره ۳، صفحات ۱۵۹-۱۶۶

Keywords
[ ' r a d i o t h e r a p y t r e a t m e n t ' , ' p a n t a k t h e r a p a x s x t ' , 1 5 0 , ' d e p t h d o s e ' , ' a p p l i c a t o r s d i a m e t e r ' , ' k v p ' , ' s u p e r f i c i a l x ' , ' r a y m a c h i n e ' ]

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023