diagnostic reference levels (drls) for routine x-ray examinations in lorestan province, iran

Authors

m. gholami department of medical physics and radiation sciences, faculty of allied medical sciences, lorestan university of medical sciences, khorram abad, iran

a. maziar department of medical physics and medical engineering, faculty of medicine, isfahan university of medical sciences, isfahan, iran

h.r. khosravi atomic energy organization of iran, tehran, iran

f. ebrahimzadeh department of biostatistics, faculty of health & nutrition, lorestan university of medical sciences, khorram abad, iran

abstract

background: in diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. secondly estimates of the absorbed dose to tissue and organs in the patients. materials and methods: a total of 2382 patients were studied to calculate the entrance surface air kerma (esak) following seven radiographic examinations including: chest (pa, lat), lumbar spines (ap, lat), pelvis (ap), abdomen (ap), skull (pa, lat), thoracic spine (ap, lat) and cervical spines (ap, lat). the esaks values were measured according to x- ray tube output, optimized exposure parameters and body thickness (tp) for each technique. results: the parameters such as, 1st quartile, mean, median, 3rd quartile, minimum, maximum and standard deviation of each esak values are reported and compared to nrpb guide levels. the results showed that the esaks values in the lumbar spines and chest x-ray examinations were 30% above the guide levels. however, for the pelvis (ap), skull (pa) and abdomen (ap) examinations, these values were below than those reported by the nrpb. conclusion: periodic quality control and monitoring the technical performance of radiographers might effectively improve the image quality and eventually reducing the dose received by patients.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Diagnostic reference levels (DRLs) for routine X-ray examinations in Lorestan province, Iran

Background: In diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. Firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. Secondly estimates of the absorbed dose to tissue and organs in the patients. Materials and Methods: A total of 2382 patients were studied t...

full text

Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

full text

Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran

Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments ...

full text

Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

full text

local diagnostic reference levels for common pediatric x-ray examinations in khorasan razavi province, iran

introduction given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. diagnostic reference level (drl) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

full text

Diagnostic reference levels for X-ray examinations in Slovenia

Background. Medical applications of ionizing radiation are by far the largest man-made source of radiation exposure for the population in most developed countries. A good practice in diagnostic radiology should produce an image containing all necessary information needed for accurate diagnosis and should result in the minimum dose to the patient. After introduction of diagnostic reference level...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of radiation research

جلد ۱۳، شماره ۱، صفحات ۸۵-۹۰

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023