impact of contrast agents on dose algorıthms of planning systems

Authors

m. izmirli department of radiation oncology, school of medicine, yuzuncu yıl university, turkey

t. çakır department of radiation oncology, school of medicine, yuzuncu yıl university, turkey

s. avcu department of radiology, school of medicine, gazi university, turkey

m. nart department of radiation oncology, school of medicine, yuzuncu yıl university, turkey

abstract

background: use of contrast agents (cas) during ct simulation for treatment planing system leads to changes in  electron density. in this study we aimed to investigate the effect on  calculated dose of various concentrations of cas on treatment planing systems in different dose calculation algorithms. materials and methods: contrast agent (0.769 mg/ml iopromid) - water mixtures at concentrations of 0%, 1%, 2%, 5% and 10% in total volume of 500 ml for each were made by using five identical balloons. calculations were performed by cobalt-60 and 10 mv linear accelerator devices in cms xio treatment planning system. the prescribed dose of 100cgy was given to the center of balloon that is isocenter of sad technique at 10cm from the surface. the doses at maximum dose depth (dmax) and at 5 cm were calculated according to the separate algorithms by either making or not making a correction for ca, and the results were recorded. results: in all algorithms, as contrast ratio increases, the dose values at dmax and 5 cm-depth increase accordingly. when the doses at dmax and 5 cm-depth were compared for linac and co-60 in all algorithms, it has been shown that the dmax value of co-60 was higher and the difference was greater in parallel with increasing contrast ratio in comparing with linac. conclusion: when required during the planning, the treatment plan should be calculated via providing an electron density correction by contouring the volume retaining cas along the beam line.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Impact of contrast agents on dose algorıthms of planning systems

Background: Use of contrast agents (CAs) during CT simulation for treatment planing system leads to changes in  electron density. In this study we aimed to investigate the effect on  calculated dose of various concentrations of CAs on treatment planing systems in different dose calculation algorithms. Materials and Methods: Contrast agent (0.769 mg/ml Iopromid) - water mixtures at con...

full text

The effect of CT contrast agents on treatment planning and dose calculation in radiation therapy of pelvis cancers

Introduction: Using contrast medium in diagnosis and identifying of an organ from its surrounding tissue is very useful. These contrast mediums alter radiation absorption of studied organs. The aim of this study is to identify the influences of contrast media in treatment planning system of the pelvis.   Materials and Methods: Seven patients with pelvis area ...

full text

the effects of planning on accuracy and complexity of iranian efl students’ written narrative task performance

this study compared the different effects of form-focused guided planning vs. meaning-focused guided planning on iranian pre-intermediate students’ task performance. the study lasted for three weeks and concentrated on eight english structures. forty five pre-intermediate iranian students were randomly assigned to three groups of guided planning focus-on-form group (gpfg), guided planning focus...

15 صفحه اول

The impact of dose calculatıon algorıthms for perıpheral dose dıstrıbutıons of enhanced dynamıc and physıcal wedges

Background: In radiation therapy, the peripheral dose is important when anatomical structures with very low dose tolerances are involved. In this study, the two available calculation algorithms of the Varian Eclipse 8.6 treatment planning system(TPS), the anisotropic analytic algorithm (AAA) and pencil-beam convolution (PBC) was used to compare measured and calculated peripheral dose distributi...

full text

the effects of time planning and task complexity on accuracy of narrative task performance

هدف اصلی این تحقیق بررسی تاثیر برنامه ریزی زمانی، هم چنین افزایش میزان پیچیدگی تکالیف در نظر گرفته شده بصورت همزمان، بر دقت و صحت و پیچیدگی عملکرد نوشتاری زبان آموزان می باشد. بدین منظور، 50 نفر از دانش آموزان دختر در رده ی سنی 16 الی 18 سال به عنوان شرکت کنندگان در این زمینه ی تحقیق در نظر گرفته شدند و به دو گروه آزمایشی و کنترل بصورت اتفاقی تقسیم شدند. اعضای گروه آزمایشی هر دو تکلیف ساده و پی...

the impact of training on second language writing assessment: a case of raters’ biasedness

چکیده هدف اول این تحقیق بررسی تأثیر آموزش مصحح بر آموزش گیرندگان براساس پایایی نمره های آنها در پنج بخش شامل محتوا ، سازمان ، لغت ، زبان و مکانیک بود. هدف دوم این بود که بدانیم آیا تفاوتهای بین آموزشی گیرندگان زن و مرد در پایایی نمرات آنها وجود دارد. برای بررسی این موارد ، ما 90 دانشجو در سطح میانه (متوسط) که از طریق تست تعیین سطح شده بودند انتخاب شدند. بعد از آنها خواستیم که درباره دو موضوع ا...

15 صفحه اول

My Resources

Save resource for easier access later


Journal title:
iranian journal of radiation research

جلد ۱۴، شماره ۱، صفحات ۲۵-۳۰

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023