pediatric dose assessment in common ct examination towards establishment of related regional drl in mazandaran, iran
Authors
abstract
background: computed tomography (ct) is main contributor of population dose from diagnostic x-ray examinations. children are more radiosensitive than adults, thus optimization of ct examination in these patients is essential. the purpose of this study was to evaluate dose delivered to pediatric patients’ undergoing ct examination of the common examinations and also establishing local diagnostic reference levels (drls). materials and methods: questionnaires were designed for data collection at seven public hospitals and information about patient, protocol and ct system were recorded during 2013 and 2014. dose measurement was performed in four age groups: 0-1, 1-5, 5-10 and 10-15 years old and two ct dose quantity including ctdiw and dlp were calculated. results: values of 40, 48, 59.5, 59.5 mgy; 16.9, 16.9, 17.14, 17.14 mgy; 17, 17, 17, 17 mgy; 17, 17, 19.2, 19.2 mgy in terms of ctdiw and 448, 538, 758, 758 mgy cm; 129, 129, 154, 167 mgy cm; 184, 225, 306, 315 mgy cm; 289, 408, 595, 670 mgy cm in terms of dlp as regional drl for brain, sinus, chest, abdomen and pelvic examinations were obtained respectively. conclusion: the variations in dose of some examination were considerable. as the role and usage of ct technology continues to expand, it is important that all practitioners adapt optimized protocols, especially for pediatrics scanning, following proposed reference levels
similar resources
Pediatric dose assessment in common CT examination towards establishment of related regional DRL in Mazandaran, Iran
Background: Computed Tomography (CT) is main contributor of population dose from diagnostic X-ray examinations. Children are more radiosensitive than adults, thus optimization of CT examination in these patients is essential. The purpose of this study was to evaluate dose delivered to pediatric patients’ undergoing CT examination of the common examinations and also establishing local Diag...
full textDose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
full textDose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
BACKGROUND Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. OBJECTIVE This study is aimed at evaluating radiation dose to patients from ...
full textdose assessment in computed tomography examination and establishment of local diagnostic reference levels in mazandaran, iran
background : medical x-rays are the largest man-made source of public exposure to ionizing radiation. while the benefits of computed tomography (ct) are well known in accurate diagnosis, those benefits are not risk-free. ct is a device with higher patient dose in comparison with other conventional radiation procedures. objective: this study is aimed at evaluating radiation dose to patients from...
full textAssessment of Patient Dose from CT Examinations in Khorasan, Iran
Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two refe...
full textanalyzing patterns of classroom interaction in efl classrooms in iran
با به کار گیری روش گفتما ن شنا سی در تحقیق حا ضر گفتا ر میا ن آموزگا را ن و زبا ن آموزا ن در کلا سهای زبا ن انگلیسی در ایرا ن مورد بررسی قرار گرفت. ا هداف تحقیق عبا رت بودند از: الف) شنا سا ئی سا ختارهای ارتبا ط گفتا ری میا ن معلمین و زبا ن آموزا ن ب) بررسی تا ثیر نقش جنسیت دبیرا ن و زبا ن آموزان بر سا ختا رهای ارتبا ط گفتا ری میا ن آنها پ) مشخص کردن اینکه آ یا آموزگاران غا لب بر این ارتبا ط گف...
My Resources
Save resource for easier access later
Journal title:
iranian journal of radiation researchجلد ۱۴، شماره ۳، صفحات ۲۵۱-۲۵۶
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023