abstract

active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. this paper proposes a control scheme based on the instantaneous active and reactive power. the inverter of this active filter is a three-phase, two-level converter. space vector technique is used as modulators and pattern generators for the pulse width modulated converter. virtual flux and a phase locked loop based on a double synchronous reference frame cause this control system be resistant to the majority of line voltage disturbances. good dynamic response, independent control of active and reactive powers and also unity power factor of converter are advantages of the proposed method. the operation of the proposed control strategy is verified in matlab simulation environment

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads

Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...

full text

Sliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition

This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...

full text

A Nonlinear Voltage Stability Index based on Vector Analysis Method and Measurements of Active and Reactive Powers of Power System

This paper proposes a new voltage stability assessment method based on vector analysis method. This index extraction process relies on measurements of active and reactive powers from connected buses to the generator buses. Therefore, a limit for beginning of voltage collapse is determined based on the maximum power transfer theory. On the other hand, when the system requires load shedding, a ne...

full text

Discrete Time Control Method for SVM Direct Active Power and Stator Flux Control of PMSG-Based Wind Turbine

This paper proposes a new method for direct control of active power and stator flux of permanent magnet synchronous generator (PMSG) used in the wind power generation system. Active power and stator flux are controlled by the proposed discrete time algorithm. Despite the commonly used vector control methods, there is no need for inner current control loops. To decrease the errors between refere...

full text

A shunt active power filter control for unbalanced conditions

This paper first presents a simple control technique for active filters to compensate current harmonics and reactive power of nonlinear loads. This method is usable for both single –phase and three –phase systems. Then a new method for load balancing and reactive power compensation for unbalanced sinusoidal load currents is presented. Finally by combination of two methods an active filter contr...

full text

Performance Scrutiny of Two Control Schemes Based on DSM and HB in Active Power Filter

This paper presents a comparative analysis between two current control strategies, constant source power and generalized Fryze current, used in Active Power Filter (APF) applications having three different modulation methods. The Hysteresis Band (HB) and first-order Delta-Sigma Modulation (DSM) as well as the second-order DSM is applied. The power section of the active power filter is viewed as...

full text