resonance frequency analysis of clinical stability of astra tech and iti implant systems
Authors
abstract
background and aims. resonance frequency analysis (rfa) offers a noninvasive clinical measurement of stability and osseointegration of implants; it is a useful tool to establish implant loading time. the rfa values are represented by a quantitative unit called the implant stability quotient (isq) on a scale from 1 to 100. the aim of the present study was to measure the stability of astra tech and iti dental implants during the healing period and determine the factors that affect the isq. materials and methods. in this study fourteen healthy subjects who were candidates for dental implants were randomly divided into two groups. group one received 15 astra tech and group two received 15 iti dental implants. bone type was classified according to the lekholm and zarb index (d1-d4). rfa was used for direct measurement of implant stability on the day of implant placement and 1, 3 and 6 months after implant placement. data were analyzed by anova, student’s t-test and spearman rank correlation test using spss 11.5 with 95% confidence interval. results. the means of isq for astra tech implant after 3 and 6 months were significantly greater than those for iti implant (p<0.05). statistical analysis showed higher isq values for mandible with type i and type ii bone than maxilla and type iii and type iv bone (p<0.05); implant diameter was significantly correlated to implant stability (p<0.05). conclusion. our data suggest that bone quality, implant surface texture (implant system) and diameter can affect implant stability and loading time.
similar resources
Clinical documentation on ASTRA TECH Implant System
The OsseoSpeed implant (also including short, narrow and Profile implants) has been extensively documented in several prospective clinical studies covering most indications such as: single-tooth restorations, fixed partial/full prostheses, and overdentures with a minimum of 1 year of follow-up . Moreover, results show that the implant can be safely used with a survival rate ranging from 94.5 to...
full textClinical documentation on ASTRA TECH Implant System
Prospective clinical data reporting on the ASTRA TECH Implant System OsseoSpeed implant shows that it can be safely used in a variety of indications in the maxilla and mandible, with a reported survival rate ranging from 94.5 to 100% , with only one exception . The same good results are reported for immediate loading protocols in the atrophic maxilla 17, , in sinus lifted/grafted posterior site...
full textResonance frequency analysis of implant stability in augmented and non-augmented sinus sites
Background and aim: Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...
full textOverdentures supported by ASTRA TECH Implant SystemTM
Prospective clinical studies with the ASTRA TECH Implant System show that the survival rate of implants placed in the mandible is the same when comparing overdentures and fixed bridges, irrespective of retaining system used . The use of a ball abutment or a Locator for a non-splinted support, as well as the use of a bar attachment for a splinted support, is well documented with a followup of 1–...
full textresonance frequency analysis of implant stability in augmented and non-augmented sinus sites
background and aim: although there have been substantial developments in dental implant therapies, achieving good implant stability (isq >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. this study aimed to evaluate and compare the time required to a...
full textcomparison of implant stability using resonance frequency analysis: osteotome versus conventional drilling
objectives: implant primary stability is one of the important factors in achieving implant success. the osteotome technique may improve primary stability in patients with poor bone quality. the aim of this study was to compare implant stability using two different techniques namely osteotome versus conventional drilling in the posterior maxilla. materials and methods: in this controlled randomi...
full textMy Resources
Save resource for easier access later
Journal title:
journal of periodontology and implant dentistryجلد ۲، شماره ۲، صفحات ۶۶-۰
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023